Anesthesia Machine
Jinling-850 Advanced Anesthesia Workstation
Precision Anesthesia Delivery & Ventilation
✔ Dual Control System – Operates in both pneumatic and electronic modes with:
-
Circuit flexibility: Closed, semi-closed, or semi-open configurations
✔ Intelligent Ventilation –
-
8 Ventilation Modes: IPPV, SIPPV, VCV, PCV, IMV, SIMV, Manual, Standby
-
Wide Parameter Range:
-
Tidal volume: 20–1500ml (display up to 2000ml)
-
Respiratory rate: 1–100 bpm
-
I/E ratio: 8:1 to 1:10
-
✔ Comprehensive Safety Systems –
-
Real-time alarms for airway pressure/tidal volume
-
4+ hour battery backup for critical procedures
-
O2/N2O pressure monitoring (medical-grade gas supply)
✔ Anesthetic Agent Compatibility –
-
Vaporizers for Enflurane, Isoflurane, Sevoflurane, Halothane
-
Concentration range: 0.5%–5%
CATEGORY: Operating Room (or “Surgery” per your list)
Key Enhancements:
-
Technical Precision – Clearly specifies ventilation modes and gas settings
-
Safety Prioritization – Highlights backup power and alarm systems
-
Structured Layout – Groups features by functionality (ventilation → safety → agents)
-
Clinical Relevance – Emphasizes OR-ready capabilities
Infant Incubator
BIN-3000AG Neonatal Incubator
Advanced Care for Premature & Newborn Infants
Core Features:
✔ Precision Climate Control –
-
Dual Temperature Modes: Air (25°C–37°C ±0.1°C) + Servo-controlled skin probe
-
Active Humidification – Maintains optimal humidity for preterm skin
✔ Safety & Monitoring –
-
Multi-Parameter Alarms (audio/visual) for temperature, humidity, O₂ (optional)
-
Oxygen Integration – Optional O₂ mixer for respiratory support
✔ Ergonomic Design –
-
360° Plexiglas Visibility with access portholes
-
Mobility: Roller base (100kg unit weight; 136×56×106cm footprint)
Technical Excellence:
-
Medical-Grade Materials – Easy-to-sanitize surfaces
-
Extended Temp Range – Safely exceeds 37°C when clinically needed
CATEGORY: Maternity & Pediatric (or “Neonatology” if separate in your system)
Key Enhancements:
-
Clinical Prioritization – Leads with preterm care benefits
-
Technical Precision – Specifies ±0.1°C accuracy and dimensions
-
Safety Emphasis – Highlights alarms/O₂ optionality
-
Correct Categorization – Aligns with your original list
Blood Pressure Monitor
Omron M1 Basic Blood Pressure Monitor
Key Features:
✔ Automatic Upper Arm Measurement –
-
Utilizes oscillometric technology with Intelligent Inflation for comfort
-
Clinically validated for accuracy
✔ Comprehensive Readings –
-
Measures systolic/diastolic pressure + pulse rate
-
22–42 cm cuff (standard adult size)
✔ User-Friendly Design –
-
One-touch operation
-
Digital display with last measurement memory
CATEGORY: Parameters & Hospitalization (from your list)
Why This Categorization?
-
“Parameters & Hospitalization” covers patient monitoring devices used in:
-
Clinical settings (hospitals/clinics)
-
Post-discharge home care
-
-
Fits better than “Instrumentation” as it directly measures vital health parameters
Electronic Baby Scale
Electronic Baby Scale – Precision Infant Growth Monitoring
Key Features:
✔ High-Precision Weighing –
-
Range: 10g–20kg (0.02–44 lb)
-
Automatic Tare Function: Deducts diaper/pad weight
-
Growth Tracking: Stores last measurement & calculates weight differences
✔ Child-Safe Design –
-
Ergonomic Platform: Contoured for infant comfort
-
Non-Toxic Materials: Easy-to-clean, hygienic surface
-
Stable Base: Prevents movement during measurements
✔ User-Friendly Operation –
-
LCD Display: Clear readings
-
Unit Conversion: kg/lb/st with one-touch switching
-
Battery-Powered: 2 AA batteries with auto shut-off & low-battery alert
Digital Thermometer
GF-MT502 Digital Thermometer
Precision Temperature Monitoring for Clinical & Home Use
Key Features:
✔ Medical-Grade Accuracy
-
Range: 32.0°C–43.0°C (±0.1°C) / 90.4°F–110.4°F (±0.1°F)
-
Fast Measurement: 10–60 seconds (site-dependent)
✔ Intuitive Design
-
Large LCD with 3-digit display
-
Audible alert when measurement completes
-
Memory recall of last reading
✔ Safety & Durability
-
Waterproof & shatter-resistant
-
Auto power-off extends battery life
-
Non-toxic materials (safe for all ages)
Certifications:
-
CE/FDA compliant (confirm based on model)
-
Clinically validated
Manual Centrifuge
NAME: Manual Centrifuge
The following are the features of the manual centrifuge:
Manual Operation:
It is operated by a hand crank, making it suitable for areas with limited access to electricity.
Maximum Speed:
It can reach a maximum speed of 3,000 rpm.
Maximum Relative Centrifugal Force (RCF):
The maximum RCF is approximately 1200 x g or 1298 g.
Capacity:
It is designed to hold four 15 ml tubes.
Mounting:
It can be secured to a bench or work surface using an adjustable screw clamp (0 to 40 mm).
Maintenance:
Its self-lubricating gear mechanism makes it virtually maintenance-free.
Upper Arm Blood Pressure Monitor
Jziki Arm Style Blood Pressure Monitor
Advanced Home Blood Pressure Tracking
Key Features:
✔ Clinically Accurate Measurement
-
Oscillometric technology (±3 mmHg / ±0.4 kPa accuracy)
-
WHO classification indicator for instant hypertension staging
✔ Comprehensive Health Insights
-
Irregular heartbeat detection (IHB alerts)
-
Pulse rate monitoring
-
2×99 memory storage (supports 2 users)
✔ User-Friendly Design
-
22-32cm adjustable cuff (fits standard arms)
-
Large LCD display shows SYS/DIA/PUL + date
-
One-touch operation with auto-inflation
✔ Power & Convenience
-
4 AAA batteries (included)
-
Auto power-off preserves battery life
Rotator Mixer
The Rotator Mixer, also referred to as a “Rucator Mixer” or model KJMR-IV, is designed for consistent mixing of biological samples or cell suspensions, such as whole blood in collection tubes.
**Key Features:**
**Mixing Motion:**
Utilizes a gentle rotating and rocking motion to achieve uniform mixing, preventing sedimentation or coagulation of samples.
**Speed:**
Offers fixed rotation speeds (e.g., 33 rpm or 36 rpm) or digitally adjustable speeds (e.g., 20–99 rpm or 4–30 rpm).
**Applications:**
Ideal for hematological testing, mixing blood samples, viscous materials, and liquid-solid suspensions.
Digital Breathalyzer
Device Type:
A compact digital breathalyzer designed to measure Breath Alcohol Concentration (BAC).
Key Components:
-
Mouthpiece for breath sampling
-
Power button
-
LCD screen for result display
-
Battery compartment (powered by 2 AAA batteries)
Performance and Accuracy:
-
Employs a semiconductor sensor to ensure accurate BAC readings
-
Quick warm-up time (~10 seconds)
-
Fast response time (~5 seconds to display results)
-
Reference point of 0.05% BAC equates to 0.05 grams of alcohol per 100 ml of blood
Advantages:
-
Reusable with hygienic, replaceable mouthpieces
-
No shelf-life limitations (unlike chemical-based breathalyzers)
-
Compact, discreet, and user-friendly
-
Clear digital readout of alcohol levels
Obstetrical Vacuum Extractor
MODEL: ENT-2023
Material Quality:
Crafted from medical-grade silicone, ensuring excellent biocompatibility, durability, and safety.
Safe and Gentle Design:
The suction head is made of soft, high-quality silicone, designed to be gentle and non-harmful to the newborn.
User-Friendly:
Offers ease of handling with flexible material that ensures secure placement and an effective vacuum seal during use.
Clinical Application:
Primarily used for vacuum-assisted vaginal deliveries, especially during the second stage of labor or in cases of prolonged or obstructed labor.
Risk Reduction:
Designed to reduce the likelihood of fetal trauma, cephalohematoma, and the need for forceps-assisted delivery.
Sterility and Reusability:
Supplied hygienically sealed for initial use and can be sterilized for safe reuse.
System Compatibility:
Compatible with any suction unit featuring a pressure gauge and release valve.
Size Options:
Available in multiple sizes—small, medium, and large—to accommodate various obstetric needs.
Anaerobic Jar
Materials:
Constructed primarily from durable stainless steel with a lid made of polycarbonate or PVC, both resistant to UV exposure and aging.
Capacity and Dimensions:
-
Volume: 2.5 liters
-
Holding Capacity: Accommodates up to 12 Petri dishes (90 mm in diameter)
Functionality:
Engineered to create and maintain anaerobic or microaerophilic conditions, enabling the cultivation of oxygen-sensitive microorganisms.
Pressure System:
-
Integrated valves for vacuuming air and introducing specific gases
-
Built-in pressure gauge for accurate control, typically ranging from -1 to +0.2 bar
Accessories and Compatibility:
-
Internal supports for Petri dishes, microtiter plates, or test tubes
-
Compatible with oxygen-removal systems such as palladium catalysts or gas-generating sachets
Application:
Essential in microbiology laboratories for the incubation and growth of anaerobic bacteria that require oxygen-free environments.
Kinlee baby scale
Capacity and Precision:
-
Maximum Capacity: 20 kg
-
Graduation: 10 g increments for accurate weight measurement
Design Features:
-
Traditional mechanical operation with an analog dial and a clear red needle for easy weight reading
-
No electronic components—ideal for reliable, maintenance-free use
Platform:
-
Wide, stable weighing platform designed for infant safety and comfort
Maintenance-Free Operation:
-
Battery-free and button-free design ensures long-term reliability and simplicity
Usage Guidelines:
-
Always place on a firm, level surface
-
Set the scale to zero before each use
-
Weigh the baby at the same time daily, without clothing or shoes
-
Ensure the baby remains still and centered on the scale during measurement
Cleaning and Care:
-
Clean using a soft, damp cloth only
-
Avoid harsh chemicals, abrasives, or soaking
-
Store in a dry place away from direct sunlight or heat sources to preserve functionality and longevity