Heating Mantle

The 250 ml laboratory heating mantle.
Key Features:

Capacity: Designed to heat round-bottomed flasks with a capacity of 250 ml.

Temperature Control: It is equipped with electronic temperature control, allowing precise heating control.

Maximum Temperature: Can reach a maximum temperature of 370°C, or even 450°C for some models.

Power: Typically 150 W.

Construction: Chemical-resistant steel or polypropylene outer shell, with thermal insulation made of mineral fiber wool or molded silica.

Safety: Some models include protective fuses and a “cool-touch” outer casing to minimize the risk of burns.

Additional Features: Some heating mantles of this capacity can also incorporate magnetic stirring, allowing the contents of the flask to be heated and stirred simultaneously.

Hematology Analyzer

Key Features:

White Blood Cell Differentiation:

  • Provides 3-part WBC differentiation, enabling clear identification of lymphocytes, monocytes, and granulocytes.

Parameters Analyzed:

  • Measures 20 to 23 parameters, including:

    • WBC, RBC, PLT, and hemoglobin (HGB), among others.

Performance:

  • Analysis Speed: Up to 60 samples per hour

  • Sample Volume: Requires just 9.8 µL of venous blood for testing

Technology:

  • Dual-channel counter for simultaneous measurements

  • Time-volume and electrical impedance measurement (Coulter principle)

  • SFT method for hemoglobin analysis

  • Advanced valve control for high-precision fluid management


User Interface & Operation:

  • 8.4-inch TFT color display with intuitive Windows-based graphical interface

  • Operable via mouse and keyboard

  • Simplified user interaction with large buttons and fast access menus

Automated Functions:

  • Automatic dilution, mixing, rinsing, unclogging

  • Automatic internal and external probe cleaning

Data Handling & Output:

  • Stores data for up to 10,000 samples with 3 histograms

  • Equipped with a built-in thermal printer

  • Supports external printer connection

  • RS232 port for PC connectivity


Design & Usability:

  • Compact, lightweight, and ergonomic build

  • Optimized for ease of use in busy lab environments

Quality Control Features:

  • Supports statistical QC parameters: X-B, L-J, X, SD, CV%

Language Support:

  • Available in English, Spanish, French, Portuguese, Italian, and Indonesian

Hematology Machine

URIT-3000Plus Hematology Analyzer – Technical Specifications

Key Features

✅ Fully Automated 3-Part Differential Analyzer
✅ High Throughput: Up to 60 samples/hour
✅ 21 Measured Parameters + 3 Histograms


Technical Specifications

Analysis Principles

  • Electrical Impedance: WBC, RBC, PLT counts

  • Photoelectric Colorimetry: HGB measurement

Performance & Efficiency

  • Sample Volume: 20 μL (capillary or venous blood)

  • Memory Capacity: 100,000+ results (with histograms)

  • Data Export: USB, HL7-compatible (LIS/HIS integration)

User Interface & Operation

  • 10.4-inch Color LCD (Linux OS)

  • Input Options:

    • Standard keyboard & mouse

    • Optional touchscreen upgrade

  • Real-time monitoring of system status

Quality & Compliance

  • Certifications: CE, ISO 13485

  • Built-in QC: Supports 3-level calibration

Maintenance & Service

  • Self-Check Diagnostics: Minimizes downtime

  • Low-Consumable Design: Cost-effective operation

Hemoglobinometer

The Mission Hb Hemoglobin Testing System features:

Fast and Accurate Measurement:
It measures hemoglobin (Hb) and hematocrit (Hct) levels in less than 15 seconds with only 10 µL of blood (capillary or venous).

Ease of Use:
The system is designed to be simple to use, with a large display for easy reading of results.

Data Storage and Transfer Capabilities:
It can store up to 1,000 test results with the date and ID, and this data can be transferred to a computer via a USB port.

Portability:
Compact and powered by 3 AAA batteries, it is ideal for in-office or mobile use.

Detection Method:
It uses reflectance photometry and the methemoglobin principle for detection.

Automatic Calibration:
For convenience and necessary.

Hemoglobinometer

BRAND: URIT-12

DESCRIPTION:

The URIT-12 is a portable hemoglobinometer designed for the rapid and reliable measurement of hemoglobin and hematocrit.

Main Features:
Parameters Measured: Hemoglobin (Hb) and hematocrit (HCT).
Measurement Principle: Optical Reflectance.
Sample: Capillary or venous whole blood (approximately 13-15 µL).
Speed: Results obtained in 10 seconds or less.
Measurement Range: 4.0 g/dL to 24.0 g/dL (g/L option available).
Memory: Storage capacity for 250 test results.
Quality Control: Uses HQ-A hemoglobin control solution.
Calibration: Factory calibrated according to the ICSH (International Council for Standardization in Hematology) standard.
Automation: Self-monitoring, self-diagnosis, and fault display.
Power supply: Operates on two CR2032 batteries (DC 6V).
Dimensions: Compact (102 mm x 50 mm x 19 mm).
Certifications: CE ISO, ensuring compliance with European standards.

HF-300 ventilators are pneumatic and microcomputer controlled

This HF-300 ventilators are pneumatic and microcomputer controlled. They are mainly A / C, SIMV, PSV, Spont, MMV, IPPV, SIGH, PEEP etc, which can set Freq., Inspiration time, Respiration hold time etc parameters to keep management for respiration, the main parts of the machine are imported in high quality level, which greatly improves the reliability and stability of the machine. The machine is reasonable in structure, convenient in operation and reliable in performance, and is suitable for emergency, ICU ward and other respiratory rescue and treatment.
Please read user’s manual before operating.

Main performance and technical index
1.
Ventilation mode and composition:
the ventilator is composed of main unit, humidifier, circuit and oxygen regulator.
Ventilation modes: A/C,SIMV,PSV,SPONT,MMV,IPPV,SIGH, PEEP;

2. Air circuit performance:
a) Maximum safety pressure of air circuit: no more than 12kpa.
b) Inspiratory oxygen concentration: 40-100% ± 15%.
c) The maximum working pressure is not greater than the upper pressure limit.

3. Ventilation performance:
a) Respiratory frequency (f): 4-99 times / min, error ± 15%.
b) Inspiratory time (TI): 0.2-6s, less than 1s ± 0.15s, and other errors ± 15%.
c) Breath holding time (TP): 0-2s, less than 1s ± 0.15s, and other errors ± 15%.
d) Trigger pressure (PT): – 2KPa~0kpa. When the inspiratory trigger pressure is – 2KPa to – 1kPa, the tolerance is ± 20%; when the inspiratory trigger pressure is – 1kPa to 0kpa, the tolerance is ± 200Pa.
e) Tidal volume (VT): 0-2000ml; when 0ml-200ml, display value tolerance ± 40ml; when 200ml-2000ml, display value tolerance ± 20%.
f) Maximum minute ventilation volume: not less than 18L / min.
g) PSV: 2-5kpa, error ± 20%
h) Peep pressure: 0.0kpa ~ 3.0KPa. When 0.0kpa-1.0kpa, the tolerance is ± 0.2kpa; when 1.0kpa-3.0kpa, the tolerance is ± 20%
i) SIMV frequency: 4-99 times / min, error ± 15%.

4. Alarm performance:
a) Pressure upper limit (PH) alarm: 2-6kpa, error ± 20%, audible and visual alarm.
b) Pressure lower limit (PL) alarm: 0.0kpa ~ 4.0kpa. When 0.0kpa-1.0kpa, the tolerance is ± 200Pa; when 1.0kpa-4.0kpa, the tolerance is ± 20%. When the airway pressure is lower than the set value of the lower pressure limit for 5s-15s, there shall be an audible and visual alarm.
c) Upper ventilation limit (MVH) alarm: audible and visual alarm when ventilation is higher than the set value.
d) Low ventilation limit (MVL) alarm: audible and visual alarm when ventilation is lower than the set value.
e) Power off alarm: power off alarm shall be given immediately, and the alarm duration shall not be less than 120s.
f) Insufficient air, insufficient oxygen alarm
g) Mute: no more than 2 minutes.

5. Monitoring performance:
a) Tidal volume (VT): 0-2000ml, 0ml-200ml, display value tolerance ± 40ml; 200ml-2000ml, display value tolerance ± 20%.
b) The measured total frequency (ftot) and autonomous frequency (fspont).
c) Minute ventilation (MV).
d) I: E ratio.
e) Peak pressure (Ppeak).
f) Peep pressure: 0.0kpa ~ 3.0KPa. When 0.0kpa-1.0kpa, the tolerance is ± 0.2kpa; when 1.0kpa-3.0kpa, the tolerance is ± 20%.

6. Overall performance:
a) Power supply: AC 220V ± 22v.50hz ± 1Hz.
b) Main unit input power: 90va.
c) Electrical safety: Meet the relevant requirements of GB9706.1-1995 medical electrical equipment Part I: General requirements for safety for class I type B equipment.
d) Noise of the whole machine: no more than 65dB (a).
e) System compliance: no more than 4ml / 100Pa.

7. Service conditions:
a) Ambient temperature: + 5 ℃ ~ + 40 ℃.
b) Relative humidity: 30% – 75%;
c) Atmospheric pressure: 96-104kpa.
d) Use air source, 0.28-0.6mpa, flow rate > 60L / min.
e) Preheating time: 5 minutes.

8. Dimension: 375 × 320 × 300 mm.

9. Net weight: 16KG.

10. Storage and transportation:
The temperature range of normal storage and transportation of this product is – 15 ℃ ~ + 40 ℃;
Relative humidity is not more than 75%, atmospheric pressure range is 50kPa ~ 106kpa, there should be no acid, alkali and corrosive gas in the room, and there should be no strong mechanical vibration, impact, strong magnetic field and well ventilated place. During transportation, it should be moisture-proof, handle with care, and pay attention to direction signs.

High Frequency Mobile C-Arm System

Brand:ARI
Model:AR-3310C

HF generator
120KV, 5KW, 40kHz
Fluoroscopy mode
Fluoroscopy mode: 40~120kV, 0.5~5mA (KV manual and automatic);
Pulsed fluoroscopy: 40~120kV, 0.5-5mA

Boost fluoroscopy: 40~120kV, 5~10mA;

Photography: 40~120kV, 1~250mAs

X ray tube
Dual-focus Rotating anode: 0.3mm/0.6mm
IMD Technology

Image intensifier
Three fields of vision 9, 6, 4.5, Japan Toshiba Brand
Image system
Recursive Noise Reduction
Frame freezing

Multi frame image storage

Image conversing and rotating

Screen display with image comparison

Mechanical motion specifications
Vertical travel: 0-400mm
Horizontal travel: 0~200mm

Rotation about horizontal axis: ±180°

C-arm dimension
Distance of focal spot to image generator(SID): 1000mm
Depth in arm: ≥650mm

Mobile stand: 1800mm*800mm*1850mm

Image system: 750mm*530mm*1680mm

Standard configuration
High resolution CCD camera: 1set
x-ray generator: 1set

9” image intensifier: 1set

image processor

15” High resolution monitor: 2sets

Mobile stand: 1 set

Dimension Two cases

High-quality medical mortuary freezer

Description :for 9 bodies YSSTG0109
Item No.: YSSTG0109
High-quality freezer and cold storage box for corpses, stainless steel corpse freezer.
Brand
YSENMED
Model Number:YSSTG0109.

High-Speed Power Homogenizer

MODEL: FSH-2A

The FSH-2A homogenizer is an adjustable high-speed homogenizer commonly used in laboratories for homogenizing various materials, including animal and plant tissues.

Main Features:

Motor Speed:
The motor can reach a speed of 22,000 rpm. The homogenizing knives have specific speed ranges: 8,000 to 18,000 rpm for the large knife and 8,000 to 20,000 rpm for the small knife.

Homogenization Features:
It uses an internal suction homogenization structure (internal cutter).
It can efficiently homogenize and emulsify two or more immiscible liquids.
It is capable of extracting trace organic compounds, fat-soluble substances, and soluble organic solvents.
It allows for the homogenization and mixing of various animal and plant tissues.
It can rupture cell membranes for separation and fragment DNA strands into small molecules at varying speeds.

Additional Features:
It can be used as a low-speed stirrer.
The speed is digitally displayed for intuitive and accurate readings.
It incorporates a high-speed thyristor control system and Hall element speed measurement with advanced electronic circuits.

Technical Specifications:
Power: 185W.
Voltage: Available in 110V or 220V.
Continuous Working Time: 3 minutes.
Capacity: Can handle volumes of 5ml, 10ml, 15ml, and 20ml.

Impedance Meter

Characteristics of an Impedance Meter Scale
An impedance meter scale is a scale that, in addition to measuring weight, estimates body composition using impedance measurement.

How it works and measurements:
Impedance measurement: The scale is equipped with electrodes that send a very low-intensity electrical current through the body. This current encounters a different resistance (impedance) depending on the tissue (muscle, fat, water).
Body composition estimation: Using the measured impedance and personal data (age, height, gender), the scale calculates the percentage of body fat, muscle mass, body water, and sometimes bone mass or visceral fat.

Key indicators: It provides information such as weight, BMI (Body Mass Index), body fat percentage, body water percentage, and muscle mass.

Common Technical Specifications:
Materials: Tempered glass, stainless steel (for the electrodes), and ABS (for the base).
Capacity and Accuracy: Typically a maximum capacity of up to 180 kg and a measurement accuracy of approximately 0.1 kg or 50 g.
Connectivity: Equipped with Bluetooth connectivity for data synchronization with a dedicated mobile app (available on iOS and Android).
Display: Clear LED or LCD display, backlit for easy readability.

Additional Features: Automatic shutoff, data storage for multiple users, progress tracking via the app.

Use:
Body Composition Monitoring: Allows you to track changes in fat and muscle mass as part of a diet or exercise program.
Personal Information: Requires data entry such as gender, age, and height for accurate calculations.

Incubator

MODEL: MK-202-0-B

The laboratory incubator, also called a constant temperature incubator, has general features including:

Temperature control:
It maintains a constant temperature, ideal for the growth of biological samples such as cells and microorganisms. The temperature range can vary, for example, from 15°C above ambient temperature to 70°C.

Safety:
It is equipped with overheating protection systems, with indicator lights (LEDs) and automatic heating circuit cutoffs if an alarm value is exceeded.

Design:
It generally features a double-door structure with an inner glass door for easy observation of samples without disturbing the internal environment. The door is equipped with a magnetic strip for easy closing and an automatic power-off function when opened for safety.
Fans with adjustable speeds and operating levels are also available.
Available in several sizes

Infant Incubator

BIN-3000AG Neonatal Incubator

Advanced Care for Premature & Newborn Infants

Core Features:
✔ Precision Climate Control –

  • Dual Temperature Modes: Air (25°C–37°C ±0.1°C) + Servo-controlled skin probe

  • Active Humidification – Maintains optimal humidity for preterm skin

✔ Safety & Monitoring –

  • Multi-Parameter Alarms (audio/visual) for temperature, humidity, O₂ (optional)

  • Oxygen Integration – Optional O₂ mixer for respiratory support

✔ Ergonomic Design –

  • 360° Plexiglas Visibility with access portholes

  • Mobility: Roller base (100kg unit weight; 136×56×106cm footprint)

Technical Excellence:

  • Medical-Grade Materials – Easy-to-sanitize surfaces

  • Extended Temp Range – Safely exceeds 37°C when clinically needed

CATEGORY: Maternity & Pediatric (or “Neonatology” if separate in your system)


Key Enhancements:

  1. Clinical Prioritization – Leads with preterm care benefits

  2. Technical Precision – Specifies ±0.1°C accuracy and dimensions

  3. Safety Emphasis – Highlights alarms/O₂ optionality

  4. Correct Categorization – Aligns with your original list