Centrifuge with Hematocrit
MODEL: SH120
DESCRIPTION:
The SH120 centrifuge with hematocrit is a laboratory device designed for the precise determination of the specific volume of blood cells and the separation of traces of blood or solutions.
Main Features:
Speed and Centrifugal Force:
It reaches a maximum speed of 12,000 rpm and a maximum relative centrifugal force (RCF) of 15,300 x g.
Capacity:
It is designed to accommodate 24 1.5 x 75 mm capillary tubes.
Motor:
It is equipped with a brushless motor, ensuring quiet, maintenance-free operation and no carbon dust pollution.
Control and Safety:
It features microcomputer control and an automatic balancing system for optimal precision. Safety features include a durable plastic housing with a metal cover, a mechanical door lock, and a safety switch.
Operation:
It is easy and safe to use, with low noise and stable performance, enabling rapid centrifugation even with small amounts of blood.
Cardiotocograph
NAME: Cardiotocograph
BRAND: Contec
MODEL: CMS800G
The Contec CMS800G fetal monitor is a compact device designed to monitor fetal heart rate (FHR), uterine contractions (TOCO), and fetal movements (FMOV).
Key Features:
Design and Display:
Compact design, can be placed horizontally or hung on a wall.
8.0-inch color LCD screen, 60° rotatable.
Clear display of monitoring waveforms and data.
Monitoring Features:
Real-time acquisition of FHR, TOCO, and FMOV.
Marking of the normal FHR zone (120 BPM~160 BPM).
Manual recording of fetal movements.
Audible and visual alarm for abnormal fetal heart rates (high or low).
Continuous 24-hour real-time monitoring.
Storage and Printing:
Storage, playback, and printing of monitoring curves and data for 12 continuous hours.
Built-in long-life, high-resolution thermal printer.
Freeze frame function.
Connectivity and Options:
Can be used standalone or connected to a central monitoring system via a built-in RJ45 port.
Optional English interface.
Twin monitoring option.
9-crystal broadband pulsed-wave transducer (or 12 crystals depending on the source).
Supports external USB flash drive and SD card functions for data storage.
Built-in rechargeable batteries ensure more than three hours of operation after a power outage.
Use:
Suitable for use in hospitals, clinics, doctor’s offices, and at home by professional medical personnel.
Gynecological Manual Vacuum Aspirator
The image shows a gynecological manual vacuum aspiration (MVA) kit, also known as a manual vacuum aspiration (MVA) kit.
Key features of the gynecological vacuum aspirator (MVA kit):
Complete kit:
It usually includes a double-valve (or single-valve) syringe, Karman cannulas of various sizes, an adapter, and lubricating oil.
Sterile and safe:
Designed for single use and sterilized to ensure maximum patient safety and prevent cross-contamination.
Precise suction control:
The double-valve syringe allows controlled negative pressure, essential for safe and effective uterine evacuation.
Lightweight and portable:
Its compact design makes it easy to handle and suitable for procedures in the clinic or on the go.
Atraumatic Cannula:
Karman cannulas are smooth, with a rounded tip and smooth orifices for atraumatic insertion and increased patient comfort.
Medical-Grade Materials:
The components are manufactured from medical-grade materials, such as polypropylene, ensuring the reliability and safety of the device.
Ultrasound Cart
The ultrasound cart has several distinct features.
Cart Features:
Mobility and Stability:
It is equipped with 5 wheels, 2 of which have brakes to ensure stability during use.
Table Top:
The table top features raised edges on the right, left, and rear sides to prevent equipment from sliding. The table top is sleek and secure, withstanding the rigors of continuous use.
Accessories and Storage:
It features a storage basket, ideal for accessories such as probes and cables. A probe holder is also included.
Cable Management:
A cable management system is integrated into the rear of the column for efficient cable organization during use, transport, and storage.
Biopsy Forceps
The objects in the image are gynecological biopsy forceps, used to collect tissue samples.
Main Features:
Use:
They are primarily used in gynecology, particularly for cervical biopsies during colposcopies, or for grasping and inserting/removing intrauterine devices (IUDs), such as the coil.
Design:
Length: They are long (e.g., 20 cm, 28 cm, 35 cm) to allow for deep use while maintaining good maneuverability.
Material: Made of surgical-grade stainless steel.
Jaws: The jaws are sharp (for biopsy) or designed for secure grasping of tissue or devices.
Handle: Scissor-shaped for easy grip and precise control.
Sterilization and Reuse:
Many biopsy forceps are designed to be reusable and autoclavable, ensuring maximum sterility for repeated use, although single-use versions are also available.
Electrocardiogram
NAME: Electrocardiogram
BRAND: SUNMED UK
MODEL: N12
The main features of the portable electrocardiograph, Model N12, are as follows:
Sampling System:
12-channel synchronous ECG sampling system.
Printing:
Built-in thermal printer using 80 mm paper for synchronized printing.
Display:
7-inch color touchscreen, allowing both push-button and touch operation.
Analysis Features:
Automatic measurement, calculation, analysis, and waveform freeze function.
Storage and Connectivity:
Supports USB flash drives and SD memory cards, and data transmission to a PC via RS232/USB.
Data Management:
Ability to enter patient information, view, and print historical data.
Power Supply:
Built-in rechargeable Li-ion battery with AC/DC power conversion.
Design:
Portable design with a hidden handle for easy transport.
Safety and Warnings:
Risk of explosion if used in the presence of flammable anesthetics.
Risk of electric shock. Do not remove the cover. Refer servicing to qualified personnel.
For fire protection, replace the fuse
with one of the same type and rating.
Poupinel
NAME: Poupinel
MODEL: OV-A25SF
A Poupinel, or dry heat sterilizer (identified as a “THERMOSTAT OVEN OV-A25SF”), is a device used for sterilizing medical or laboratory instruments using dry hot air.
Its main features are as follows:
Composition and Structure:
Watertight, double-walled metal enclosure, made of stainless steel (inside and out), with a hermetic door.
A fan is included for even distribution of hot air.
Stainless steel trays to accommodate the instruments to be sterilized.
Operation and Performance:
Sterilization using dry hot air, without pressure increase.
Adjustable temperature range, typically between 50°C and 250°C, with temperature stability.
Heating by shielded elements for rapid temperature rise.
Safety and Control:
Temperature control systems: hydraulic or electronic thermostat, thermometer.
Timer for automatic shutdown after a set time (e.g., 0 to 120 minutes).
Built-in safety thermostat to prevent overheating.
Indicator lights indicate operation or possible anomalies.
Applications:
Primarily used for rapid sterilization of surgical, dental, or other medical and laboratory instruments.
Not suitable for sterilizing materials that are poor heat conductors.
Pump body
Pump bodies are used for blood collection. Their main features are:
Increased safety:
Designed to separate the needle from the collection tube, they prevent incidents related to splashing and clotting of the collected blood.
Compatibility:
Their size is suitable for 13 mm and 16 mm diameter collection tubes, as well as blood culture tubes.
Perforated Adhesive Plaster
The characteristics of the 18 cm x 5 m perforated adhesive tape are as follows:
Dimensions:
18 cm wide and 5 meters long.
Adhesive Type:
Zinc oxide-based or synthetic, latex-free for some models.
Backing:
Non-stretch fabric, such as fibranne or a similar textile backing.
Perforation:
Perforations (holes) allow air and moisture permeability, promoting better skin tolerance.
Adhesion:
Strong adhesiveness for secure fixation of dressings or care equipment, while being designed not to affect normal skin function.
Ease of Use:
Often tearable by hand in both directions for convenient application.
Indications:
Used for holding dressings in place and securing catheters or other medical equipment.
Gauze Compress
The specific characteristics of the gauze compress are as follows:
Gauze type: Zigzag gauze.
Dimensions: 65 cm x 100 m.
Weave: 40S x 40S, 19 x 15 threads (weave density).
Packaging: IPC (Individually Packed).
Batch number: 2024081.
General characteristics of gauze compresses:
Gauze compresses, like the one shown, are medical devices commonly used for wound care and hygiene.
Composition:
They are generally made from absorbent cotton, which makes them soft and absorbent.
Use:
They are intended to absorb bleeding and exudate, clean and disinfect wounds, or make dressings.
Sterility:
They can be sterile (for surgical procedures or infected wounds) or non-sterile (for daily care without the risk of infection).
Folding:
A surgical fold with tucked edges is often used to prevent fraying and minimize the risk of irritation or contamination.
Absorbency:
Their woven structure ensures high liquid absorption capacity.
Automatic Film Processor
Model: TS350-N
The automatic analog X-ray film processor, also known as the TS350-N Automatic Analog X-ray Film Processor.
Main Features:
Function: This device is designed to automatically process films used in analog radiology.
Application: It is used in the field of medical imaging for processing X-ray images.