Electrolyte Analyser

Analysis method: Uses the Ion Selective Electrode (ISE) method.
Parameters measured: Capable of measuring potassium (K), sodium (Na), and chlorine (Cl), with the ability to expand to include calcium (Ca), lithium (Li) and pH.
Speed of analysis: Performs tests quickly, with a speed of approximately 45-60 seconds per sample.
Compatible samples: Ideal for analysing electrolytes in a variety of sample types such as serum, plasma, cerebrospinal fluid and diluted urine.
Electrode: Features a high-precision, long-life electrode.
Operation: Designed for ease of use with an intuitive menu.
Calibration: Features a self-calibration function.
Operating conditions: Recommended working temperature between 5 and 40°C, and relative humidity less than or equal to 80%.

Electronic Baby Scale

Electronic Baby Scale – Precision Infant Growth Monitoring

Key Features:

✔ High-Precision Weighing –

  • Range: 10g–20kg (0.02–44 lb)

  • Automatic Tare Function: Deducts diaper/pad weight

  • Growth Tracking: Stores last measurement & calculates weight differences

✔ Child-Safe Design –

  • Ergonomic Platform: Contoured for infant comfort

  • Non-Toxic Materials: Easy-to-clean, hygienic surface

  • Stable Base: Prevents movement during measurements

✔ User-Friendly Operation –

  • LCD Display: Clear readings

  • Unit Conversion: kg/lb/st with one-touch switching

  • Battery-Powered: 2 AA batteries with auto shut-off & low-battery alert

Electronic Bathroom Scale

The electronic bathroom scale features are as follows:

Specifications:
Weight Capacity: 2.5 kg – 150 kg / 180 kg (5-396 lbs)
Display: Four-digit LCD display
Battery: CR2032 LI 3V / 2 x 1.5V batteries
Operating Temperature Range: 10-35°C (50-95°F)
Auto Shutoff: In 10 seconds
Display Indicators:
Err“: Indicates an error or incorrect weight.
OL“: Indicates an overload (Out of Limit).

Operating Instructions:
Remove the battery protection tab before first use.
Place the scale on a hard, flat surface.
Step on the scale and wait for the weight to display and stabilize.
The weight will flash on the display for 10 seconds.
The scale will turn off automatically.
Replace the battery when the “LO” indicator appears.

Cautions/Precautions:
Do not leave any objects on the scale when not in use.
Stand in the center of the scale to avoid slipping and ensure accurate weighing.
Avoid dropping or impacting the scale.
The surface is made of tempered glass and may break if mistreated.
Clean the surface with a clean, dry cloth.
Do not immerse the scale in water.
To reset the scale, remove the battery, wait at least 10 seconds, then reinsert it.

Electronic Room Thermometer

MODEL: HTC-1

The HTC-1 electronic room thermometer features the following:

Main Functions:
Simultaneous display of temperature, humidity, and time.
Clock and calendar function (month and date).
Alarm clock function.
Memorization of maximum and minimum temperature and humidity values.

Measuring Ranges:
Temperature: -50°C to +70°C (-58°F to +158°F).
Humidity: 10% to 99% RH (Relative Humidity).

Accuracy:
Temperature: ±1°C (±1.8°F).
Humidity: ±5% RH.

Resolution:
Temperature: 0.1°C (0.2°F).
Humidity: 1% RH.

Display:
Large LCD screen.
Selectable 12-hour/24-hour time display system.
Selectable °C/°F temperature units.

Power supply: 1 x 1.5V AAA battery (not included).

Dimensions and placement:
Product dimensions: approximately 92 x 84 x 22mm.
Can be placed on a desk or mounted on a wall.
Material: Plastic

Electronic Upper Arm Blood Pressure Monitor

The upper arm blood pressure monitor has the following features:

Device Type: Cuff-style electronic blood pressure monitor.

Display: LCD digital display.

Features: Blood pressure (SYS/DIA) and pulse (PUL) measurement, memory function (MEM), HD English voice broadcast (VOI), and setting (SET) and start/stop (START/STOP) buttons.

Cuff: Designed for an arm circumference of 22 to 32 cm, with a placement indication of 2 to 3 cm above the elbow.

Power: Battery operated (not visible but implied for this type of device).

Certification: CE certified and RoHS compliant.

Measurement: Uses the oscillometric method with automatic inflation by air pump.

Electronic Upper Arm Blood Pressure Monitor

MODEL: BP-103H

DESCRIPTION:

The features of the BP-103H, a fully automatic upper arm blood pressure monitor, are as shown and confirmed.
Measurement Type: Fully automatic measurement of blood pressure (systolic and diastolic) and pulse rate.
Measurement Method: Uses the oscillometric method to detect blood pressure and heart rate.

Display: Simultaneously displays systolic (SYS), diastolic (DIA), and pulse rate (PUL) values.

Memory: Storage capacity for 120 measurements with date and time stamp.

WHO Indicator: Includes a World Health Organization (WHO) indicator for easy interpretation of results.

Use: Designed for home or clinical use, with an upper arm cuff.

Power: Battery operated.
Reliability: Robust and reliable devices, often with a warranty.

Electronic Wrist Blood Pressure Monitor

MODEL: CK-W133

The CK-W133 wrist blood pressure monitor has the following features:

Type: Automatic wrist blood pressure monitor.
Display: Large digital LCD screen for easy reading of measurements, date, and time.

Measurements: Measures systolic pressure (SYS), diastolic pressure (DIA), and pulse rate (PUL).

Features: Irregular heartbeat detection.
Memory function (up to 90 readings for two users).
Auto shut-off to save battery life.
Simple one-touch operation.

Measuring Range:
Pressure: 0-280 mmHg.
Pulse: 40-199 beats/min.
Accuracy: Pressure: ±3 mmHg; Pulse: ±5%.
Power supply: Requires two AAA batteries (not included).

Cuff: Adjustable wrist cuff (circumference from 135 to 195 mm)

Electrophoresis Device

MODEL: JY600

DESCRIPTION:

The specifications of the JY600 electrophoresis power supply are as follows:
Output Type: Constant Voltage or Constant Current.
Output Range:
Voltage: 5 to 600 V.
Current: 1 to 200 mA.
Maximum Power: 120 W.
Resolution: 1 V, 1 mA.
Timer Range: 1 minute to 9 hours and 59 minutes.
Display: Dual LED digital display showing voltage, current, and power values.

Control: Intelligent microprocessor control unit.

Protection Functions: Automatic detection of no-load, overload, short circuit, rapid resistance change, ground leakage, and system overheating.

Other features:
Automatic memory function.
Automatic switching function.
Touch control panel.
Two sets of output jacks.
Molded shell.

Electrophoresis Machine

Electrophoresis Machine – Model DY-300

DESCRIPTION:
The DY-300 is a horizontal electrophoresis system designed for precise separation of charged particles, including DNA, RNA, and proteins, based on their migration rates in an electric field.

Key Features:

✔ Microprocessor Control & Digital Display – Allows precise adjustment and real-time monitoring of parameters.
✔ Advanced Safety Protections – Includes overtemperature alarms, electrical leakage protection, automatic cutoff, and post-operation alerts.
✔ High-Performance Electrical Output – DC 300V, 100mA with adjustable ranges (0-100V / 0-200V, 0-100mA / 0-200mA).
✔ Durable & Sterile Construction – Made with medical-grade materials, featuring a stainless steel interior and glass inner door with hidden locks.
✔ Global Certifications – Compliant with CE, FDA, EEC, ISO 13485, MSDS, and NAFDAC-registered for medical use.

Electrostimulator

The features of a transcutaneous electrical nerve stimulation (TENS) device, such as the one pictured, typically include the following:

How it works: A TENS device is a small, battery-powered unit that delivers a weak electrical current through adhesive electrodes placed on the skin. These electrical impulses stimulate the nerves in the targeted area to help block or alter the transmission of pain signals to the brain.

Components: It consists of a main unit (often the size of a small cell phone), connecting wires, and several sets of adhesive electrodes.

Adjustable settings: The user can typically adjust the intensity, frequency, and duration of the electrical impulses to find a comfortable and effective level.

Operating Modes: TENS machines often offer different modes, such as a continuous mode (constant tingling sensation) and a burst mode (pulsing sensation).

Portability: These devices are generally lightweight and portable, allowing them to be used during a variety of activities, with the exception of showering, swimming, or driving in some cases.

Applications: TENS devices are used to relieve various types of pain, including back pain, joint pain, neuralgia, menstrual cramps, and pain related to musculoskeletal injuries.

Technical Specifications (vary by model):

Frequency: For example, 1 to 250 Hz.
Pulse Width: For example, 20 to 250 microseconds.
Number of Channels: Some models have two or four channels.
Power Source: Often a 9-volt battery or dual power supply (mains/battery).
Display: A graphic LCD display is common.

ELISA Reader

Model: URIT-660

The URIT-660 is a microplate reader designed for immunoassay analysis in clinical laboratories. Its key features include:

Reading Capabilities:
It can read 96-well plates and other plate formats, with 8 reading channels allowing an entire plate to be read in 5 seconds.

Optical System:
It is equipped with an 8V/20W halogen lamp light source and filters at specific wavelengths (e.g., 405nm, 450nm, 492nm, 630nm).

User Interface:
It features a large touchscreen LCD display for intuitive operation.

Advanced Features: The URIT-660 offers extensive onboard data analysis, a choice of microplate shaking speeds, and storage capacity for up to 10,000 test results.

Connectivity:
It can be connected to optional PC control software and features serial (RS-232) and parallel interfaces for an external printer.

ELISA Washer

MODEL: Urit-670

The ELISA washer is an essential laboratory device designed for cleaning microplates used in ELISA (Enzyme-Linked Immunosorbent Assay) tests. Its main features are designed to ensure efficient and precise washing, minimizing residue and cross-contamination.

General Features of an ELISA Washer:
Adjustable Wash Parameters:
Allows you to adjust the volume, speed, and number of wash cycles to suit different analytical needs.

Microplate Compatibility:
Generally compatible with various types of microplates (flat, U-shaped, V-shaped).

Aspirating and Dispensing System:
Includes washing heads to aspirate and dispense washing solutions into the microplate wells.

Liquid Management:
Uses bottles for wash solutions and waste, often equipped with level sensors to prevent overflow and breakdowns.

Advanced Features:
Some models incorporate features such as automatic distilled water rinsing, pump pressure control to prevent needle clogging, and special rinsing procedures to reduce contamination.

Easy Maintenance:
Detachable components (such as the microplate holder or manifolds) facilitate cleaning and maintenance of the device.