Hepatitis C
The DiaSpot HCV Rapid Diagnostic Test features are as follows:
Test Type: Rapid Diagnostic Test.
Use: Intended for in vitro diagnostic use only.
Target: Detection of HCV (Hepatitis C Virus).
Storage Conditions: Store sealed at any temperature between 2 and 30°C (36-86°F).
Reagent Origin: Reagents are made in the USA.
Hepatitis C
The following are the main features of the HIGHTOP HCV (Hepatitis C Virus) One-Step Rapid Test:
Test Type: Rapid lateral flow chromatographic immunoassay for the qualitative detection of hepatitis C virus (HCV) antibodies.
Applicable Specimens: Whole blood, serum, or plasma.
Rapid Results: Results are available in 10 to 20 minutes.
Ease of Use: Simple to use, requiring no specialized equipment, and results can be read visually.
Sensitivity and Specificity: High sensitivity and specificity.
Storage Conditions: Stable at room temperature (2-30°C).
Format: Available in strip or cassette form.
Principle: Based on the principle of the dual-antigen sandwich immunoassay for the determination of anti-HCV.
Intended Use: Aid in the diagnosis of hepatitis C virus infection.
HF-300 ventilators are pneumatic and microcomputer controlled
This HF-300 ventilators are pneumatic and microcomputer controlled. They are mainly A / C, SIMV, PSV, Spont, MMV, IPPV, SIGH, PEEP etc, which can set Freq., Inspiration time, Respiration hold time etc parameters to keep management for respiration, the main parts of the machine are imported in high quality level, which greatly improves the reliability and stability of the machine. The machine is reasonable in structure, convenient in operation and reliable in performance, and is suitable for emergency, ICU ward and other respiratory rescue and treatment.
Please read user’s manual before operating.
Main performance and technical index
1.
Ventilation mode and composition:
the ventilator is composed of main unit, humidifier, circuit and oxygen regulator.
Ventilation modes: A/C,SIMV,PSV,SPONT,MMV,IPPV,SIGH, PEEP;
2. Air circuit performance:
a) Maximum safety pressure of air circuit: no more than 12kpa.
b) Inspiratory oxygen concentration: 40-100% ± 15%.
c) The maximum working pressure is not greater than the upper pressure limit.
3. Ventilation performance:
a) Respiratory frequency (f): 4-99 times / min, error ± 15%.
b) Inspiratory time (TI): 0.2-6s, less than 1s ± 0.15s, and other errors ± 15%.
c) Breath holding time (TP): 0-2s, less than 1s ± 0.15s, and other errors ± 15%.
d) Trigger pressure (PT): – 2KPa~0kpa. When the inspiratory trigger pressure is – 2KPa to – 1kPa, the tolerance is ± 20%; when the inspiratory trigger pressure is – 1kPa to 0kpa, the tolerance is ± 200Pa.
e) Tidal volume (VT): 0-2000ml; when 0ml-200ml, display value tolerance ± 40ml; when 200ml-2000ml, display value tolerance ± 20%.
f) Maximum minute ventilation volume: not less than 18L / min.
g) PSV: 2-5kpa, error ± 20%
h) Peep pressure: 0.0kpa ~ 3.0KPa. When 0.0kpa-1.0kpa, the tolerance is ± 0.2kpa; when 1.0kpa-3.0kpa, the tolerance is ± 20%
i) SIMV frequency: 4-99 times / min, error ± 15%.
4. Alarm performance:
a) Pressure upper limit (PH) alarm: 2-6kpa, error ± 20%, audible and visual alarm.
b) Pressure lower limit (PL) alarm: 0.0kpa ~ 4.0kpa. When 0.0kpa-1.0kpa, the tolerance is ± 200Pa; when 1.0kpa-4.0kpa, the tolerance is ± 20%. When the airway pressure is lower than the set value of the lower pressure limit for 5s-15s, there shall be an audible and visual alarm.
c) Upper ventilation limit (MVH) alarm: audible and visual alarm when ventilation is higher than the set value.
d) Low ventilation limit (MVL) alarm: audible and visual alarm when ventilation is lower than the set value.
e) Power off alarm: power off alarm shall be given immediately, and the alarm duration shall not be less than 120s.
f) Insufficient air, insufficient oxygen alarm
g) Mute: no more than 2 minutes.
5. Monitoring performance:
a) Tidal volume (VT): 0-2000ml, 0ml-200ml, display value tolerance ± 40ml; 200ml-2000ml, display value tolerance ± 20%.
b) The measured total frequency (ftot) and autonomous frequency (fspont).
c) Minute ventilation (MV).
d) I: E ratio.
e) Peak pressure (Ppeak).
f) Peep pressure: 0.0kpa ~ 3.0KPa. When 0.0kpa-1.0kpa, the tolerance is ± 0.2kpa; when 1.0kpa-3.0kpa, the tolerance is ± 20%.
6. Overall performance:
a) Power supply: AC 220V ± 22v.50hz ± 1Hz.
b) Main unit input power: 90va.
c) Electrical safety: Meet the relevant requirements of GB9706.1-1995 medical electrical equipment Part I: General requirements for safety for class I type B equipment.
d) Noise of the whole machine: no more than 65dB (a).
e) System compliance: no more than 4ml / 100Pa.
7. Service conditions:
a) Ambient temperature: + 5 ℃ ~ + 40 ℃.
b) Relative humidity: 30% – 75%;
c) Atmospheric pressure: 96-104kpa.
d) Use air source, 0.28-0.6mpa, flow rate > 60L / min.
e) Preheating time: 5 minutes.
8. Dimension: 375 × 320 × 300 mm.
9. Net weight: 16KG.
10. Storage and transportation:
The temperature range of normal storage and transportation of this product is – 15 ℃ ~ + 40 ℃;
Relative humidity is not more than 75%, atmospheric pressure range is 50kPa ~ 106kpa, there should be no acid, alkali and corrosive gas in the room, and there should be no strong mechanical vibration, impact, strong magnetic field and well ventilated place. During transportation, it should be moisture-proof, handle with care, and pay attention to direction signs.
HF2 Small Fragment Kit
Surgical instrument set, identified as an HF2 Small Fragment Kit, with a diameter of 5.0 mm.
Features of this type of kit may include:
- Single Lock Monoaxial Screws
- General Instrument Set
- Locking Head Cancellous Screws Fully Threaded
- Mesh Plates
- Mini Plates without Bridge
- 4.5 mm Locking Condylar Buttress Plates
- 3.5 mm Calcaneal Locking Plates (Left/Right)
- fixLOCK Instrument Set – Large
High Frequency Mobile C-Arm System
Brand:ARI
Model:AR-3310C
HF generator
120KV, 5KW, 40kHz
Fluoroscopy mode
Fluoroscopy mode: 40~120kV, 0.5~5mA (KV manual and automatic);
Pulsed fluoroscopy: 40~120kV, 0.5-5mA
Boost fluoroscopy: 40~120kV, 5~10mA;
Photography: 40~120kV, 1~250mAs
X ray tube
Dual-focus Rotating anode: 0.3mm/0.6mm
IMD Technology
Image intensifier
Three fields of vision 9, 6, 4.5, Japan Toshiba Brand
Image system
Recursive Noise Reduction
Frame freezing
Multi frame image storage
Image conversing and rotating
Screen display with image comparison
Mechanical motion specifications
Vertical travel: 0-400mm
Horizontal travel: 0~200mm
Rotation about horizontal axis: ±180°
C-arm dimension
Distance of focal spot to image generator(SID): 1000mm
Depth in arm: ≥650mm
Mobile stand: 1800mm*800mm*1850mm
Image system: 750mm*530mm*1680mm
Standard configuration
High resolution CCD camera: 1set
x-ray generator: 1set
9” image intensifier: 1set
image processor
15” High resolution monitor: 2sets
Mobile stand: 1 set
Dimension Two cases
High-Concentration Oxygen Mask
The characteristics of a high-concentration oxygen mask, such as the one presented, are as follows:
High Oxygen Concentration:
It delivers a high concentration of oxygen, thanks to its integrated reservoir bag, which ensures a constant supply to meet the patient’s respiratory needs.
Patient Comfort:
Made of soft vinyl or hypoallergenic, latex-free PVC, it offers optimal comfort and minimizes the risk of allergies. The mask is soft and pliable, fitting comfortably on the patient’s face.
Safety:
It has a built-in check valve that prevents the backflow of exhaled air and ensures a controlled, leak-free flow of oxygen.
Patient Observation:
The mask is transparent, allowing for better observation of the patient by healthcare personnel.
Mobility:
The 210 cm long oxygen tube provides the patient with a certain freedom of movement.
Single Use:
These masks are generally single-use and individually wrapped for hygiene reasons.
High-quality medical mortuary freezer
Description :for 9 bodies YSSTG0109
Item No.: YSSTG0109
High-quality freezer and cold storage box for corpses, stainless steel corpse freezer.
Brand
YSENMED
Model Number:YSSTG0109.
High-Speed Power Homogenizer
MODEL: FSH-2A
The FSH-2A homogenizer is an adjustable high-speed homogenizer commonly used in laboratories for homogenizing various materials, including animal and plant tissues.
Main Features:
Motor Speed:
The motor can reach a speed of 22,000 rpm. The homogenizing knives have specific speed ranges: 8,000 to 18,000 rpm for the large knife and 8,000 to 20,000 rpm for the small knife.
Homogenization Features:
It uses an internal suction homogenization structure (internal cutter).
It can efficiently homogenize and emulsify two or more immiscible liquids.
It is capable of extracting trace organic compounds, fat-soluble substances, and soluble organic solvents.
It allows for the homogenization and mixing of various animal and plant tissues.
It can rupture cell membranes for separation and fragment DNA strands into small molecules at varying speeds.
Additional Features:
It can be used as a low-speed stirrer.
The speed is digitally displayed for intuitive and accurate readings.
It incorporates a high-speed thyristor control system and Hall element speed measurement with advanced electronic circuits.
Technical Specifications:
Power: 185W.
Voltage: Available in 110V or 220V.
Continuous Working Time: 3 minutes.
Capacity: Can handle volumes of 5ml, 10ml, 15ml, and 20ml.
Hindfoot arthrodesis screws
IBS compression and neutralization screws are cannulated, self-drilling, and self-tapping.
The IBS compression screw is specifically designed to distribute compression force and promote bone synthesis.
They are made of Ti6AI4V titanium alloy.
Hinged Knee Brace
The image shows a Fit Geno Hinged Knee Brace, designed for knee support and pain relief.
Support and Pain Relief: This knee brace is recommended for knee support and pain relief, including meniscus tears, sprains, mild osteoarthritis, and other ligament problems (PCL/MCL/LCL).
Design and Materials: It features lateral stabilizers and removable hinges for increased stability. Made with medical-grade materials, including a patellar gel pad, it is also latex-free.
Comfort and Fit: The design features an open patella and open back to reduce pressure and prevent sweat buildup. Non-slip silicone strips and adjustable straps ensure a secure fit during activity.
Recommendations: It is recommended by sports medicine specialists and is designed to maintain joint stability while allowing mobility.
Hip abduction orthosis
The hip abduction orthosis pictured is a medical device designed to stabilize the hip joint and maintain proper alignment, particularly after surgery or injury.
Its main features include:
Support and stabilization: It is used to hold the femoral head in the acetabulum and limit the leg’s range of motion, thus promoting healing and reducing pain.
Materials: Typically made from materials such as stainless steel for durability and structural support, and breathable fabrics to prevent moisture buildup and improve comfort.
Comfort: Features padding and cushioning for increased comfort during extended wear.
Adjustability: Often equipped with adjustable straps and closures (such as Velcro) for a custom, secure fit, adapting to different sizes and body shapes.
Pediatric Functionality: Pediatric versions, such as the Rhino Cruiser Pediatric Hip Abduction Brace, are specifically designed to keep children’s legs and hips apart to ensure stability and proper hip development.
Post-operative Use: It is crucial for post-operative recovery, particularly after hip revision surgery, by providing protection and proper positioning.
Hip Orthosis
The Bort CoxaPro hip orthosis, shown in the image, has several key features:
Functionality and Mobilization: It is designed to ensure the function and/or mobilization of the hip joint.
Motion Limitation: It allows for simple limitation of flexion and extension movement.
Tool-Free Adjustment: Extension and flexion can be adjusted without tools to specific angles: 0°, 15°, 30°, 45°, 60°, 75°, 90°.
Trochanteric Pad: Includes a trochanteric pad for intermittent massage.
Splint Adaptation: The joint splint at the hip and thigh is adaptable thanks to cold molding (aluminum splint).
Functional Safety: Ensures good functional safety of the hip joint thanks to two wide, opposing reins on the thigh.
Comfort and Material: Its design is lightweight and slim for high wearing comfort. It is made of high-quality cotton-based functional knit, which is particularly resistant to Velcro.