Urine Pregnancy Test

Hightop HCG Pregnancy Test Strips have the following features:

Test Type: One-Step Rapid Test, using a strip for the detection of human chorionic gonadotropin (hCG) in urine.

Ease of Use: Designed for ease of use, without the need for complex equipment.

Accuracy: Provides high accuracy in pregnancy detection.

Speed ​​of Response: Provides rapid results.

Early Detection: Allows early detection of pregnancy by detecting hCG, a hormone produced shortly after conception.

Format: Each strip is individually wrapped in a foil pouch for hygiene reasons.

Sensitivity: Typical sensitivity is 25 mIU/mL.

Quantity: The package contains a specific number of tests; “50T” indicates 50 tests.

Rapid Test Strip of Syphilis

The HIGHTOP One Step Syphilis Ab (S/P) Rapid Test features are as follows:

Test Type: Lateral flow immunochromatographic rapid test, designed for screening.

Detection: It detects anti-syphilis antibodies (TP Ab) in serum or plasma samples.

Antigens Used: Uses purified recombinant syphilis antigens as capture materials in the test strip.

Mechanism: If anti-syphilis antibodies are present in the sample at a concentration above the threshold, a complex forms, indicating a positive result.

Ease of Use: The test is designed for ease of use.

Accuracy: Offers high accuracy.

Speed: Provides rapid results.

Quantity: The package contains 50 tests.

Hepatitis C

The DiaSpot HCV Rapid Diagnostic Test features are as follows:

Test Type: Rapid Diagnostic Test.

Use: Intended for in vitro diagnostic use only.

Target: Detection of HCV (Hepatitis C Virus).

Storage Conditions: Store sealed at any temperature between 2 and 30°C (36-86°F).

Reagent Origin: Reagents are made in the USA.

Drug Test

The features of the “Hightop One Step Rapid Test Multi Drugs Panel 12” are as follows:

Test Type: One-step rapid test for the detection of multiple drugs.

Ease of Use: Easy to use.

Accuracy: High accuracy.

Speed: Fast response.

Substances Detected: 12-drug panel, including PCP, MDMA, BAR, COC, OPI, MOP, THC, AMP, TCA, MTD, MET, and KET.

Packaging: Box of 20 tests (“20T”).

Certification: Approved.

Technology: Uses technology and innovation to improve quality of life.

Purpose: Designed for in vitro diagnostic (IVD) use.

Blue and white Ultrasound Gel

Aqua Ultrasound Gel

  • This product is a conductive gel used for ultrasound examinations.
  • It is designed to facilitate the transmission of ultrasound waves between the probe and the skin, thus enabling clear images.
  • This gel is generally water-based, non-irritating, and easy to clean.
  • It is commonly used in hospitals, clinics, and doctor’s offices for various medical imaging applications.

Capacity: 5 liters

Wash Bottle

The characteristics of the plastic wash bottle are as follows:

Material: Made of soft plastic, such as PE (polyethylene) or HDPE (high-density polyethylene), making it lightweight and easy to squeeze.
Capacity: Available in different capacities, 250 ml, 500 ml, with visible graduations to measure the volume of liquid.

Design:
Curved Spout: Features a long, curved spout for precise control of the flow and direction of the liquid, ideal for rinsing or dosing.
Narrow Mouth: For controlled filling and to prevent spills.
Transparency: The transparent body makes it easy to see the level and type of liquid contained.

Use:
Laboratory: Commonly used in laboratories for cleaning instruments with distilled water, for adding alcohol, solvents, or other washing solutions.

Others
Ease of use: The squeezable body allows for easy and controlled dispensing of liquid with a simple squeeze.

Female Urinal

The features of the portable female urinal are as follows:

Design: It has an anatomical shape specially adapted for use by women, allowing it to be used while sitting, standing, or lying down. It features a built-in handle for easy carrying and handling.

Material: Made of lightweight and durable polypropylene plastic, making it easy to clean and reusable.

Capacity and Measurement: It is graduated, allowing for the measurement of urine volume, and its capacity is generally 500 ml.

Use: Designed for people with mobility difficulties, such as bedridden patients or those with limited mobility, as well as for outdoor activities and travel.

Hygiene: Its design is designed to prevent leaks and spills, and the non-porous material helps maintain hygiene.

Central Venous Catheter

Central Venous Catheter Kit Features
The central venous catheter kit has the following features:

Catheter Type: 7Fr-20cm Triple Lumen Catheter (7 French, 20 cm long).
Material: Radiopaque polyurethane with FlexTip.

Included Components:
Indwelling catheter with integral extension line, extension line clamp, and integral suture wing.
Guidewire (straight soft tip on one end, “J” tip on the other) with advancement.

Attachment: Catheter clamp.

Introducer Needle: 18G x 2-3/5″ (6.5 cm).
5 ml Syringe / 5 ml Guidewire Introducer Syringe.
Clamp(s).
Vessel Dilator: 8Fr x 4″ (10 cm). Injection Cap(s).
No. 7 Injection Needle.

Flow Rates:
Distal: 54 ml/min.
Medial: 20 ml/min.
Proximal: 20 ml/min.

Intended Use: Superior vena cava catheterization using the Seldinger technique for short-term infusion therapy, parenteral nutrition, administration of hyperosmolar or venous irritant solutions, intermittent or continuous venous pressure monitoring, and blood sampling.

Sterility: Sterile; do not use if the package is opened or damaged. Fluid path components are non-pyrogenic and do not contain any drugs.

Single use only; do not resterilize. Sterilized with ethylene oxide.

Latex-Free: Yes.

Traceability Information:
Lot Number: WF240496.
Sterilization Date: 2024-04-08.
Conformity: CE Mark (2460).
Warning: Read all warnings, precautions, and instructions in the package leaflet before use to avoid serious patient injury or death.

Blood Glucose Test Strips

OneTouch Ultra Blood Glucose Test Strips feature the following features

DoubleSure™ Technology: Automatically checks each blood sample twice to confirm the result, ensuring proven accuracy.

FastDraw™ Capillary Action: Automatically draws blood into the strip for quick and easy sample collection.

Small Sample Size: Requires only a small drop of blood, making testing less painful.

Fast Results: Provides results in as little as five seconds.

Visual Confirmation: Makes it easy to see when there is enough blood for an accurate reading.

Compatibility: Designed for use with the OneTouch Ultra family of meters, including the OneTouch Ultra 2, UltraMini, UltraSmart, UltraLink, and the OneTouch Ping Meter Remote.

Alternative testing options: Allows glucose levels to be tested on sites other than the fingertip (e.g., the forearm), after consulting a healthcare professional.

Hemoglobin Test Strips

The characteristics of the URIT H12 hemoglobin test strips, used with the URIT-12 hemoglobin meter, are as follows:

Sample Type: Capillary or venous whole blood (13 to 15 µL, equivalent to one drop of blood).

Measurement Principle: Optical reflectance (dry chemistry colorimetric method, azidomethemoglobin method).

Measured Parameters: Hemoglobin and hematocrit (HCT).

Measurement Speed: Results obtained in 10 seconds or less.

Measurement Range: 4.0 g/dL to 24.0 g/dL (results outside this range are indicated by “Lo” or “Hi”).

Accuracy: ≥ 95%.

Calibration: Factory calibrated according to the ICSH (International Council for Standardization in Haematology) standard.

Memory: Can store up to 250 test results.

Automation: Self-checking, automatic judgment, and malfunction display.

Strip Storage Conditions: Store in a dry, dark place between 0°C and 30°C, away from direct sunlight and heat, and not frozen.

Use: Strips should be used immediately after removal from the container; used strips should be disposed of as normal medical waste.

Restrictions on Use: Not for serum, plasma, arterial blood, or patient self-testing; intended for use by healthcare professionals.

Scalpel Blade

The characteristics of surgical blades are as follows:

Product Type: Surgical Blades

Material: Single-use carbon steel

Sterilization: Sterilized by gamma radiation (25KGY) and ready to use (sterile).

Quantity: Box of 100 pieces

Certification: CE Mark 0197

Packaging: Individually wrapped in foil or peel-off aluminum pouches to maintain sterility.

Use: Single-use only

Compatibility: Compatible with stainless steel scalpel handles, depending on the blade size.

Quality: Renowned for their initial sharpness and durability, ideal for precise incisions.

Carbol Fuchsin

Carbol Fuchsin is a staining solution used primarily in microbiology, with specific characteristics and uses.

Key Features:
Composition: It is a mixture of phenol and basic fuchsin.
Use in staining: It is essential for staining mycobacteria, particularly in the Ziehl-Neelsen method, due to its affinity for the mycolic acids present in their waxy cell walls.
Resistance to decolorization: Mycobacteria stained with carbol fuchsin are resistant to decolorization by acidic alcohol, allowing them to be distinguished from other bacteria.
Microscopic Appearance: Acid-fast bacteria appear red or magenta-red under the microscope after staining with carbol fuchsin. Stability: The solution should be stored in an airtight, light-resistant container at a temperature below 40°C, preferably between 15 and 30°C, avoiding freezing.

Main Applications:
Disease Diagnosis: Crucial in the diagnosis of diseases such as tuberculosis and leprosy, as it helps identify the responsible acid-fast bacteria.
Microbiology Research: Used for the microscopic study of acid-fast bacteria and the staining of bacterial spores.
Topical Medical Use: Can be used as a first aid antiseptic for certain skin conditions where there is excess moisture.