Mobile color Ultrasound machine

Model:P60

Description

Hardware

P60 Main Unit

21.5″ High Resolution Medical Monitor

13.3″ High Resolution Touch Screen

Height Adjustable and Rotatable Operation Panel

Five Active Probe Ports

One Pencil Probe Port

Build-in ECG Module (Including Hardware and Software)

External Gel Warmer (temperature adjustable)

Built-in Wireless Adapter

1TB Hard Disk Drive, HDMI Output and USB 3.0 Ports

 

Software

B (2B & 4B) Mode

M Mode

Anatomic M Mode

Color M Mode

Color Doppler Flow Imaging

Power Doppler Imaging / Directional Power Doppler Imaging

Tissues Doppler Imaging

Pulse Wave Doppler Imaging

Continuous Wave Doppler Imaging

High Pulse Repeat Frequency

Tissue Harmonic Imaging

Pulse Inversion Harmonic Imaging

Spatial Compound Imaging

Tissue Specific Imaging

Image Rotation

μ-Scan: 2D Speckle Reduction Technology

3D μ-Scan: 3D Speckle Reduction Technology

SR Flow (High Resolution Flow)

Simultaneous Mode (Triplex)

FreeHand 3D Imaging

B Mode Panoramic Imaging / Color Panoramic Imaging

Lateral Gain Compensation

Trapezoid Imaging

Widescan Imaging (Convex Extended Imaging)

Biopsy Guide

Vis-needle (Needle Visualization Enhancement)

Auto Bladder Volume Measurement

Zoom (Pan-Zoom / HD-Zoom / Scr-Zoom)

TEI Index

PW Auto Trace

Auto IMT

Auto EF

Auto NT

Auto OB: BPD / HC / AC / FL / HL

S-Guide

C-xlasto (Strain Elastography)

Build-in User Mannual (Help)

Sono-help (Scanning Tutorial)

DICOM 3.0: Store / C-Store / Worklist / MPPS / Print / SR / Q&R

 

Applications

Basic Measurement Package

Gynecology Measurement Package

Obstetrics Measurement Package

Small Part Measurement Package

Urology Measurement Package

Vascular Measurement Package

Pediatrics Measurement Package

Abdomen Measurement Package

Cardiac Measurement Package

Pelvic Floor Measurement Package.

Electro-encephalogram (EEG)

KT88-2400 Digital Brain Electric Activity Mapping collects EEG signal with electrodes, via integrated amplification, A/D transformation, PC auto-analysis, FFT, to form electroencephalogram that displays with color depth. The product is applicable for checking such diseases as epilepsy, intracranial inflammation, cerebrovascular diseases and brain tumors.

Features

Method of 10/20 electrodes placement under international standard system, leads can be changed during replaying. Support different types of combined leads during sampling.

Adopt bioelectricity amplifier for distilling brainwave, continuous recording time can be up to 24 hours, integrated full-automatic calibration system.

Powerful playback function: amplitude and display speed are adjustable. The special subdividing time line divides the waveform in one second into 5 parts, which is easy for doctors to look over the waveform.

Digital filter system can be set as required, providing different window types

EEG signal clipping function, analyze and store any section of EEG wave, and select several waveform segments for automatically analyzing and distilling to different parameters.

Electronic frequency ruler, convenient to measure the basic information of any appointed EEG waveform. With partial enlarging window, accurate measurement of EEG period, amplitude and frequency, which can be adjusted according to personnel judgment.

Mark EEG wave under the events of opening eyes, closing eyes and flashing with different colors, and user-defined events can be added, waveform color for evoked event can also be set freely, ensures that the waveform in corresponding time can be rapidly found by event name during case playback.

Powerful automatic analysis function, can carry through the power spectrum analysis and pathologic wave detection for appointed waveform. Many graphs can be displayed in the same screen, including kinds of BEAM, numerical BEAM, compressed spectrum graph, trend graph, and so on.

Professional isolation transformer, dual power supply isolation system and optoelectronic data transmission to ensure security. Use USB interface to transmit data which just need to be inserted.

Multifunctional flash stimulator of USB interface, and flashing can be controlled manually or automatically. A flash stimulation scheme can be set and performed in the process of sampling.

Perfect case management function, provides many means for research and quick statistic information; convenient case export and import function, and stores with MO or CD-RW disk, which is easy for data research.

Integrative image and character report, report can be edited in mode and switched to Word document.

Case files can be transformed into EDF and BDF data format, convenient for data exchange, academic exchange and further analysis.

System parameters and display modes can be set as required, which meets different user’s requirement.

Add marks and annotations to the waveform designated, which can rapidly find the waveform in that time by marks.

Optional video function: USB camera is easy to install, convenient to use and exact to record. With flexible playback function, which can browse the waveform of any time along with the corresponding isochronous sampled image.

SpO2 function is optional.

Not all optional functions are available in all regions, please contact us for details.

HF-300 ventilators are pneumatic and microcomputer controlled

This HF-300 ventilators are pneumatic and microcomputer controlled. They are mainly A / C, SIMV, PSV, Spont, MMV, IPPV, SIGH, PEEP etc, which can set Freq., Inspiration time, Respiration hold time etc parameters to keep management for respiration, the main parts of the machine are imported in high quality level, which greatly improves the reliability and stability of the machine. The machine is reasonable in structure, convenient in operation and reliable in performance, and is suitable for emergency, ICU ward and other respiratory rescue and treatment.
Please read user’s manual before operating.

Main performance and technical index
1.
Ventilation mode and composition:
the ventilator is composed of main unit, humidifier, circuit and oxygen regulator.
Ventilation modes: A/C,SIMV,PSV,SPONT,MMV,IPPV,SIGH, PEEP;

2. Air circuit performance:
a) Maximum safety pressure of air circuit: no more than 12kpa.
b) Inspiratory oxygen concentration: 40-100% ± 15%.
c) The maximum working pressure is not greater than the upper pressure limit.

3. Ventilation performance:
a) Respiratory frequency (f): 4-99 times / min, error ± 15%.
b) Inspiratory time (TI): 0.2-6s, less than 1s ± 0.15s, and other errors ± 15%.
c) Breath holding time (TP): 0-2s, less than 1s ± 0.15s, and other errors ± 15%.
d) Trigger pressure (PT): – 2KPa~0kpa. When the inspiratory trigger pressure is – 2KPa to – 1kPa, the tolerance is ± 20%; when the inspiratory trigger pressure is – 1kPa to 0kpa, the tolerance is ± 200Pa.
e) Tidal volume (VT): 0-2000ml; when 0ml-200ml, display value tolerance ± 40ml; when 200ml-2000ml, display value tolerance ± 20%.
f) Maximum minute ventilation volume: not less than 18L / min.
g) PSV: 2-5kpa, error ± 20%
h) Peep pressure: 0.0kpa ~ 3.0KPa. When 0.0kpa-1.0kpa, the tolerance is ± 0.2kpa; when 1.0kpa-3.0kpa, the tolerance is ± 20%
i) SIMV frequency: 4-99 times / min, error ± 15%.

4. Alarm performance:
a) Pressure upper limit (PH) alarm: 2-6kpa, error ± 20%, audible and visual alarm.
b) Pressure lower limit (PL) alarm: 0.0kpa ~ 4.0kpa. When 0.0kpa-1.0kpa, the tolerance is ± 200Pa; when 1.0kpa-4.0kpa, the tolerance is ± 20%. When the airway pressure is lower than the set value of the lower pressure limit for 5s-15s, there shall be an audible and visual alarm.
c) Upper ventilation limit (MVH) alarm: audible and visual alarm when ventilation is higher than the set value.
d) Low ventilation limit (MVL) alarm: audible and visual alarm when ventilation is lower than the set value.
e) Power off alarm: power off alarm shall be given immediately, and the alarm duration shall not be less than 120s.
f) Insufficient air, insufficient oxygen alarm
g) Mute: no more than 2 minutes.

5. Monitoring performance:
a) Tidal volume (VT): 0-2000ml, 0ml-200ml, display value tolerance ± 40ml; 200ml-2000ml, display value tolerance ± 20%.
b) The measured total frequency (ftot) and autonomous frequency (fspont).
c) Minute ventilation (MV).
d) I: E ratio.
e) Peak pressure (Ppeak).
f) Peep pressure: 0.0kpa ~ 3.0KPa. When 0.0kpa-1.0kpa, the tolerance is ± 0.2kpa; when 1.0kpa-3.0kpa, the tolerance is ± 20%.

6. Overall performance:
a) Power supply: AC 220V ± 22v.50hz ± 1Hz.
b) Main unit input power: 90va.
c) Electrical safety: Meet the relevant requirements of GB9706.1-1995 medical electrical equipment Part I: General requirements for safety for class I type B equipment.
d) Noise of the whole machine: no more than 65dB (a).
e) System compliance: no more than 4ml / 100Pa.

7. Service conditions:
a) Ambient temperature: + 5 ℃ ~ + 40 ℃.
b) Relative humidity: 30% – 75%;
c) Atmospheric pressure: 96-104kpa.
d) Use air source, 0.28-0.6mpa, flow rate > 60L / min.
e) Preheating time: 5 minutes.

8. Dimension: 375 × 320 × 300 mm.

9. Net weight: 16KG.

10. Storage and transportation:
The temperature range of normal storage and transportation of this product is – 15 ℃ ~ + 40 ℃;
Relative humidity is not more than 75%, atmospheric pressure range is 50kPa ~ 106kpa, there should be no acid, alkali and corrosive gas in the room, and there should be no strong mechanical vibration, impact, strong magnetic field and well ventilated place. During transportation, it should be moisture-proof, handle with care, and pay attention to direction signs.

Endoscopy Video Processor SV-M2K30

The Endoscopy video processor SV-M2K30 offers advanced imaging capabilities for precise medical diagnostics. It delivers high-resolution visuals, supporting both HD and 4K imaging for enhanced clarity during endoscopic procedures.

Water Distiller

The water distiller shown in the image has several typical features:
Main Function: It is designed to produce distilled water by heating water to 100°C to transform it into vapor, then condensing it back to a liquid state, thus removing impurities.
Capacity: 5 liters and can produce approximately 1 liter of distilled water per hour.

Materials: The interior is made of high-quality stainless steel to ensure the hygiene and purity of the distilled water.

Safety: It is equipped with safety features such as automatic shutoff in case of overheating or insufficient water level, thus protecting both the device and the user.

Design: It is compact and easy to use and clean, with components accessible for maintenance.

Applications: The distilled water produced is suitable for a variety of uses, including medical institutions, laboratories, battery factories, beauty salons, and household use.

Water Distiller

Available in 10 and 20 liters

The laboratory stainless steel electric water distiller.
Here are its main features:
Material: Made of high-quality stainless steel.

Safety: Automatically cuts off the heating power supply in case of water shortage.

Condensation: Coil-type condensation structure for good cooling effect and high water production.

Water Saving: Cooling water returns to the evaporation barrel to save water resources.

Maintenance: Drain valve to drain concentrated water and improve scaling conditions.

Heating: Copper immersion heating tube with high thermal efficiency and long service life.

Capacity and Power: Available in different capacities (10L, 20L) with corresponding power ratings (e.g., 4.5 kW for 20L/h). Certifications: CE and ISO certified.

Electrophoresis Device

MODEL: JY600

DESCRIPTION:

The specifications of the JY600 electrophoresis power supply are as follows:
Output Type: Constant Voltage or Constant Current.
Output Range:
Voltage: 5 to 600 V.
Current: 1 to 200 mA.
Maximum Power: 120 W.
Resolution: 1 V, 1 mA.
Timer Range: 1 minute to 9 hours and 59 minutes.
Display: Dual LED digital display showing voltage, current, and power values.

Control: Intelligent microprocessor control unit.

Protection Functions: Automatic detection of no-load, overload, short circuit, rapid resistance change, ground leakage, and system overheating.

Other features:
Automatic memory function.
Automatic switching function.
Touch control panel.
Two sets of output jacks.
Molded shell.

Visual Acuidity Chart

The standard logarithmic visual acuity chart, also known as the modified Snellen chart or LogMAR (Logarithm of the Minimum Angle of Resolution) chart.

Primary Use: This chart is used to assess a person’s visual acuity, i.e., the sharpness of their vision.

Structure: It displays “E” letters of various sizes and orientations (up, down, left, or right) across several lines. The letters decrease in size as you move down the chart.

Formulas: The chart includes formulas for calculating visual acuity (V) and design distance (D), as well as the LogMAR (L) value, which is a logarithmic measure of visual acuity.

Test Distance: A design distance of 2.5 meters is specified for the test.

Additional Tests: At the bottom of the table, there are circles with colored numbers, suggesting an integrated color vision test (Ishihara type) to detect potential deficits.

Water Bath

MEDELE: DK-420

DESCRIPTION

The DK420 water bath is a laboratory appliance designed for heating and incubating samples at a controlled and stable temperature.
Key Features of the DK-420 Water Bath:
Temperature Control: It is equipped with a digital thermostat that allows precise and automatic temperature control, with a digital display for easy reading. The typical temperature range extends from room temperature +5°C to 99°C or 100°C.
Design and Materials: The DK420 water bath features two stainless steel tanks for corrosion resistance and ease of cleaning, and a high-quality outer casing, sometimes made of powder-coated sheet steel.
Safety and Performance: Heating with a water bath prevents sample burnout, ensuring gentle and uniform heating.
Applications: It is widely used in laboratories for applications such as distillation, concentration, drying, incubation, tempering of emulsions or solutions, and temperature testing.

Technical specifications (example based on similar models):
Capacity: 10 liters for the DK-420 model.
Power: 1000W.
Timer: Includes a timer function, ranging from 0 to 999 minutes.
Voltage: Available in various voltages, such as 110V 60Hz or 220V 50Hz.

Two-jar Surgical Aspirator

MODEL: YX930D

The image shows a YX930D Surgical Aspirator.
Its main features are as follows:
Design and Mobility:
Fully plastic panel, unique and aesthetic design.
Easily transportable thanks to its compact design and weight (approximately 19.5 kg).
Mounted on casters for easy movement between departments.
Suction Performance:
Uses an oil-free vacuum pump, providing high flow rate and rapid negative pressure, without pollution.
Maximum negative pressure: ≥0.09 MPa (680 mmHg).
Flow Rate: ≥40 L/min.

Features and Safety:
Two 2500 ml glass fluid collection jars, each with an overflow prevention device to prevent liquid from entering the pump.
Air filter to protect the pump from pollution.
Suction control via a hand switch and/or foot pedal, providing hands-free operation.
Low noise level (≤60dB(A)).

Use:
Designed for suctioning liquids (mucus, blood) in surgical or intensive care settings.

Heating Mantle

The 250 ml laboratory heating mantle.
Key Features:

Capacity: Designed to heat round-bottomed flasks with a capacity of 250 ml.

Temperature Control: It is equipped with electronic temperature control, allowing precise heating control.

Maximum Temperature: Can reach a maximum temperature of 370°C, or even 450°C for some models.

Power: Typically 150 W.

Construction: Chemical-resistant steel or polypropylene outer shell, with thermal insulation made of mineral fiber wool or molded silica.

Safety: Some models include protective fuses and a “cool-touch” outer casing to minimize the risk of burns.

Additional Features: Some heating mantles of this capacity can also incorporate magnetic stirring, allowing the contents of the flask to be heated and stirred simultaneously.

Centrifuge

MODEL: 80-1

DESCRIPTION

It offers several key features:

Capacity and Speed

It is designed for a capacity of 80 ml and can reach a maximum speed of 4000 revolutions per minute (rpm).

Use:

This model is commonly used in various laboratory applications, including hospitals, chemistry, and biology for analytical experiments.

Features:

It is equipped with a variable speed control and a timer, and can accommodate six 20 ml tubes.

Design:

The 80-1 centrifuge is described as a versatile and reliable piece of equipment for laboratories.