{"id":17496,"date":"2025-08-04T17:16:24","date_gmt":"2025-08-04T17:16:24","guid":{"rendered":"https:\/\/orickmedicosarl.com\/?post_type=product&#038;p=17496"},"modified":"2025-08-11T17:05:31","modified_gmt":"2025-08-11T17:05:31","slug":"coagulometer","status":"publish","type":"product","link":"https:\/\/orickmedicosarl.com\/index.php\/product\/coagulometer\/","title":{"rendered":"Coagulometer"},"content":{"rendered":"<h3><strong>URIT 610 Semi-Automatic Coagulometer \u2013 Technical Specifications<\/strong><\/h3>\n<h4><strong>Key Features<\/strong><\/h4>\n<p class=\"ds-markdown-paragraph\">\u2705\u00a0<strong>4-Channel Multi-Parameter Analysis<\/strong><br \/>\n\u2705\u00a0<strong>Advanced Interference Resistance<\/strong>\u00a0(HIL-resistant)<br \/>\n\u2705\u00a0<strong>Compact &amp; Efficient Design<\/strong><\/p>\n<hr \/>\n<h3><strong>Technical Specifications<\/strong><\/h3>\n<h4><strong>Operating Principle<\/strong><\/h4>\n<ul>\n<li>\n<p class=\"ds-markdown-paragraph\"><strong>Dual-Magnetic Circuit Method<\/strong>\u00a0with mechanical bead detection<\/p>\n<\/li>\n<li>\n<p class=\"ds-markdown-paragraph\"><strong>Optical Detection System<\/strong>\u00a0for clot formation<\/p>\n<\/li>\n<\/ul>\n<h4><strong>Performance &amp; Capacity<\/strong><\/h4>\n<ul>\n<li>\n<p class=\"ds-markdown-paragraph\"><strong>Simultaneous Testing:<\/strong>\u00a04 independent channels<\/p>\n<\/li>\n<li>\n<p class=\"ds-markdown-paragraph\"><strong>Throughput:<\/strong>\u00a0Up to\u00a0<strong>100 tests\/hour<\/strong><\/p>\n<\/li>\n<li>\n<p class=\"ds-markdown-paragraph\"><strong>Sample\/Reagent Capacity:<\/strong><\/p>\n<ul>\n<li>\n<p class=\"ds-markdown-paragraph\"><strong>16-sample incubator<\/strong>\u00a0(pre-warmed to 37\u00b0C)<\/p>\n<\/li>\n<li>\n<p class=\"ds-markdown-paragraph\"><strong>4 dedicated reagent wells<\/strong><\/p>\n<\/li>\n<\/ul>\n<\/li>\n<\/ul>\n<h4><strong>Measured Parameters<\/strong><\/h4>\n<div class=\"markdown-table-wrapper\">\n<table>\n<thead>\n<tr>\n<th>Parameter<\/th>\n<th>Abbreviation<\/th>\n<th>Clinical Application<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>Prothrombin Time<\/td>\n<td>PT<\/td>\n<td>Warfarin monitoring<\/td>\n<\/tr>\n<tr>\n<td>Activated Partial Thromboplastin Time<\/td>\n<td>APTT<\/td>\n<td>Heparin therapy<\/td>\n<\/tr>\n<tr>\n<td>Thrombin Time<\/td>\n<td>TT<\/td>\n<td>Fibrinogen disorders<\/td>\n<\/tr>\n<tr>\n<td>Fibrinogen<\/td>\n<td>FIB<\/td>\n<td>Clotting factor assessment<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<h4><strong>Advanced Technology<\/strong><\/h4>\n<ul>\n<li>\n<p class=\"ds-markdown-paragraph\"><strong>HIL (Hemolysis\/Icterus\/Lipemia) Compensation<\/strong>\u00a0\u2013 Reduces false results<\/p>\n<\/li>\n<li>\n<p class=\"ds-markdown-paragraph\"><strong>Auto-calibration<\/strong>\u00a0for reagent batches<\/p>\n<\/li>\n<li>\n<p class=\"ds-markdown-paragraph\"><strong>Built-in QC<\/strong>\u00a0with Levey-Jennings charts<\/p>\n<\/li>\n<\/ul>\n<h4><strong>User Interface<\/strong><\/h4>\n<ul>\n<li>\n<p class=\"ds-markdown-paragraph\"><strong>LCD Touchscreen<\/strong>\u00a0for intuitive operation<\/p>\n<\/li>\n<li>\n<p class=\"ds-markdown-paragraph\"><strong>Printer Connectivity<\/strong>\u00a0for instant reports<\/p>\n<\/li>\n<li>\n<p class=\"ds-markdown-paragraph\"><strong>LIS Compatibility<\/strong>\u00a0via RS-232\/USB<\/p>\n<\/li>\n<\/ul>\n<hr \/>\n<h3><strong>Workflow Advantages<\/strong><\/h3>\n<p class=\"ds-markdown-paragraph\">\u2714\u00a0<strong>Error Reduction<\/strong>\u00a0\u2013 Minimizes manual steps<br \/>\n\u2714\u00a0<strong>Rapid Results<\/strong>\u00a0\u2013 &lt;10 mins for most assays<br \/>\n\u2714\u00a0<strong>Cost-Effective<\/strong>\u00a0\u2013 Low reagent consumption<\/p>\n<p class=\"ds-markdown-paragraph\"><strong>Ideal for:<\/strong><\/p>\n<ul>\n<li>\n<p class=\"ds-markdown-paragraph\">Hospital coagulation labs<\/p>\n<\/li>\n<li>\n<p class=\"ds-markdown-paragraph\">Anticoagulation clinics<\/p>\n<\/li>\n<li>\n<p class=\"ds-markdown-paragraph\">Research institutions<\/p>\n<\/li>\n<\/ul>\n<hr \/>\n<h3><strong>Quality Assurance<\/strong><\/h3>\n<ul>\n<li>\n<p class=\"ds-markdown-paragraph\"><strong>CE Marked<\/strong>\u00a0&amp;\u00a0<strong>ISO 13485 Certified<\/strong><\/p>\n<\/li>\n<li>\n<p class=\"ds-markdown-paragraph\"><strong>Includes:<\/strong><\/p>\n<ul>\n<li>\n<p class=\"ds-markdown-paragraph\">Starter reagent kit<\/p>\n<\/li>\n<li>\n<p class=\"ds-markdown-paragraph\">Cleaning supplies<\/p>\n<\/li>\n<li>\n<p class=\"ds-markdown-paragraph\">Operation manual<\/p>\n<\/li>\n<\/ul>\n<\/li>\n<\/ul>\n","protected":false},"excerpt":{"rendered":"<h3><strong>URIT 610 Semi-Automatic Coagulometer \u2013 Technical Specifications<\/strong><\/h3>\n<h4><strong>Key Features<\/strong><\/h4>\n<p class=\"ds-markdown-paragraph\">\u2705\u00a0<strong>4-Channel Multi-Parameter Analysis<\/strong><br \/>\n\u2705\u00a0<strong>Advanced Interference Resistance<\/strong>\u00a0(HIL-resistant)<br \/>\n\u2705\u00a0<strong>Compact &amp; Efficient Design<\/strong><\/p>\n<hr \/>\n<h3><strong>Technical Specifications<\/strong><\/h3>\n<h4><strong>Operating Principle<\/strong><\/h4>\n<ul>\n<li>\n<p class=\"ds-markdown-paragraph\"><strong>Dual-Magnetic Circuit Method<\/strong>\u00a0with mechanical bead detection<\/p>\n<\/li>\n<li>\n<p class=\"ds-markdown-paragraph\"><strong>Optical Detection System<\/strong>\u00a0for clot formation<\/p>\n<\/li>\n<\/ul>\n<h4><strong>Performance &amp; Capacity<\/strong><\/h4>\n<ul>\n<li>\n<p class=\"ds-markdown-paragraph\"><strong>Simultaneous Testing:<\/strong>\u00a04 independent channels<\/p>\n<\/li>\n<li>\n<p class=\"ds-markdown-paragraph\"><strong>Throughput:<\/strong>\u00a0Up to\u00a0<strong>100 tests\/hour<\/strong><\/p>\n<\/li>\n<li>\n<p class=\"ds-markdown-paragraph\"><strong>Sample\/Reagent Capacity:<\/strong><\/p>\n<ul>\n<li>\n<p class=\"ds-markdown-paragraph\"><strong>16-sample incubator<\/strong>\u00a0(pre-warmed to 37\u00b0C)<\/p>\n<\/li>\n<li>\n<p class=\"ds-markdown-paragraph\"><strong>4 dedicated reagent wells<\/strong><\/p>\n<\/li>\n<\/ul>\n<\/li>\n<\/ul>\n<h4><strong>Measured Parameters<\/strong><\/h4>\n<div class=\"markdown-table-wrapper\">\n<table>\n<thead>\n<tr>\n<th>Parameter<\/th>\n<th>Abbreviation<\/th>\n<th>Clinical Application<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>Prothrombin Time<\/td>\n<td>PT<\/td>\n<td>Warfarin monitoring<\/td>\n<\/tr>\n<tr>\n<td>Activated Partial Thromboplastin Time<\/td>\n<td>APTT<\/td>\n<td>Heparin therapy<\/td>\n<\/tr>\n<tr>\n<td>Thrombin Time<\/td>\n<td>TT<\/td>\n<td>Fibrinogen disorders<\/td>\n<\/tr>\n<tr>\n<td>Fibrinogen<\/td>\n<td>FIB<\/td>\n<td>Clotting factor assessment<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<h4><strong>Advanced Technology<\/strong><\/h4>\n<ul>\n<li>\n<p class=\"ds-markdown-paragraph\"><strong>HIL (Hemolysis\/Icterus\/Lipemia) Compensation<\/strong>\u00a0\u2013 Reduces false results<\/p>\n<\/li>\n<li>\n<p class=\"ds-markdown-paragraph\"><strong>Auto-calibration<\/strong>\u00a0for reagent batches<\/p>\n<\/li>\n<li>\n<p class=\"ds-markdown-paragraph\"><strong>Built-in QC<\/strong>\u00a0with Levey-Jennings charts<\/p>\n<\/li>\n<\/ul>\n<h4><strong>User Interface<\/strong><\/h4>\n<ul>\n<li>\n<p class=\"ds-markdown-paragraph\"><strong>LCD Touchscreen<\/strong>\u00a0for intuitive operation<\/p>\n<\/li>\n<li>\n<p class=\"ds-markdown-paragraph\"><strong>Printer Connectivity<\/strong>\u00a0for instant reports<\/p>\n<\/li>\n<li>\n<p class=\"ds-markdown-paragraph\"><strong>LIS Compatibility<\/strong>\u00a0via RS-232\/USB<\/p>\n<\/li>\n<\/ul>\n<hr \/>\n<h3><strong>Workflow Advantages<\/strong><\/h3>\n<p class=\"ds-markdown-paragraph\">\u2714\u00a0<strong>Error Reduction<\/strong>\u00a0\u2013 Minimizes manual steps<br \/>\n\u2714\u00a0<strong>Rapid Results<\/strong>\u00a0\u2013 &lt;10 mins for most assays<br \/>\n\u2714\u00a0<strong>Cost-Effective<\/strong>\u00a0\u2013 Low reagent consumption<\/p>\n<p class=\"ds-markdown-paragraph\"><strong>Ideal for:<\/strong><\/p>\n<ul>\n<li>\n<p class=\"ds-markdown-paragraph\">Hospital coagulation labs<\/p>\n<\/li>\n<li>\n<p class=\"ds-markdown-paragraph\">Anticoagulation clinics<\/p>\n<\/li>\n<li>\n<p class=\"ds-markdown-paragraph\">Research institutions<\/p>\n<\/li>\n<\/ul>\n<hr \/>\n<h3><strong>Quality Assurance<\/strong><\/h3>\n<ul>\n<li>\n<p class=\"ds-markdown-paragraph\"><strong>CE Marked<\/strong>\u00a0&amp;\u00a0<strong>ISO 13485 Certified<\/strong><\/p>\n<\/li>\n<li>\n<p class=\"ds-markdown-paragraph\"><strong>Includes:<\/strong><\/p>\n<ul>\n<li>\n<p class=\"ds-markdown-paragraph\">Starter reagent kit<\/p>\n<\/li>\n<li>\n<p class=\"ds-markdown-paragraph\">Cleaning supplies<\/p>\n<\/li>\n<li>\n<p class=\"ds-markdown-paragraph\">Operation manual<\/p>\n<\/li>\n<\/ul>\n<\/li>\n<\/ul>\n","protected":false},"featured_media":17497,"comment_status":"open","ping_status":"closed","template":"","meta":[],"product_brand":[202],"product_cat":[213],"product_tag":[],"class_list":{"0":"post-17496","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_brand-urit","7":"product_cat-medicaldevices","9":"first","10":"instock","11":"taxable","12":"shipping-taxable","13":"product-type-simple"},"_links":{"self":[{"href":"https:\/\/orickmedicosarl.com\/index.php\/wp-json\/wp\/v2\/product\/17496","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/orickmedicosarl.com\/index.php\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/orickmedicosarl.com\/index.php\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/orickmedicosarl.com\/index.php\/wp-json\/wp\/v2\/comments?post=17496"}],"version-history":[{"count":1,"href":"https:\/\/orickmedicosarl.com\/index.php\/wp-json\/wp\/v2\/product\/17496\/revisions"}],"predecessor-version":[{"id":17498,"href":"https:\/\/orickmedicosarl.com\/index.php\/wp-json\/wp\/v2\/product\/17496\/revisions\/17498"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/orickmedicosarl.com\/index.php\/wp-json\/wp\/v2\/media\/17497"}],"wp:attachment":[{"href":"https:\/\/orickmedicosarl.com\/index.php\/wp-json\/wp\/v2\/media?parent=17496"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/orickmedicosarl.com\/index.php\/wp-json\/wp\/v2\/product_brand?post=17496"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/orickmedicosarl.com\/index.php\/wp-json\/wp\/v2\/product_cat?post=17496"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/orickmedicosarl.com\/index.php\/wp-json\/wp\/v2\/product_tag?post=17496"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}