{"id":18719,"date":"2025-09-17T13:40:05","date_gmt":"2025-09-17T13:40:05","guid":{"rendered":"https:\/\/orickmedicosarl.com\/?post_type=product&#038;p=18719"},"modified":"2025-09-17T13:40:40","modified_gmt":"2025-09-17T13:40:40","slug":"hemoglobin-test-strips","status":"publish","type":"product","link":"https:\/\/orickmedicosarl.com\/index.php\/product\/hemoglobin-test-strips\/","title":{"rendered":"Hemoglobin Test Strips"},"content":{"rendered":"<p>The characteristics of the URIT H12 hemoglobin test strips, used with the URIT-12 hemoglobin meter, are as follows:<\/p>\n<p><strong>Sample Type:<\/strong> Capillary or venous whole blood (13 to 15 \u00b5L, equivalent to one drop of blood).<\/p>\n<p><strong>Measurement Principle:<\/strong> Optical reflectance (dry chemistry colorimetric method, azidomethemoglobin method).<\/p>\n<p><strong>Measured Parameters:<\/strong> Hemoglobin and hematocrit (HCT).<\/p>\n<p><strong>Measurement Speed:<\/strong> Results obtained in 10 seconds or less.<\/p>\n<p><strong>Measurement Range:<\/strong> 4.0 g\/dL to 24.0 g\/dL (results outside this range are indicated by &#8220;Lo&#8221; or &#8220;Hi&#8221;).<\/p>\n<p><strong>Accuracy:<\/strong> \u2265 95%.<\/p>\n<p><strong>Calibration:<\/strong> Factory calibrated according to the ICSH (International Council for Standardization in Haematology) standard.<\/p>\n<p><strong>Memory:<\/strong> Can store up to 250 test results.<\/p>\n<p><strong>Automation:<\/strong> Self-checking, automatic judgment, and malfunction display.<\/p>\n<p><strong>Strip Storage Conditions:<\/strong> Store in a dry, dark place between 0\u00b0C and 30\u00b0C, away from direct sunlight and heat, and not frozen.<\/p>\n<p><strong>Use:<\/strong> Strips should be used immediately after removal from the container; used strips should be disposed of as normal medical waste.<\/p>\n<p><strong>Restrictions on Use:<\/strong> Not for serum, plasma, arterial blood, or patient self-testing; intended for use by healthcare professionals.<\/p>\n","protected":false},"excerpt":{"rendered":"<p>The characteristics of the URIT H12 hemoglobin test strips, used with the URIT-12 hemoglobin meter, are as follows:<\/p>\n<p><strong>Sample Type:<\/strong> Capillary or venous whole blood (13 to 15 \u00b5L, equivalent to one drop of blood).<\/p>\n<p><strong>Measurement Principle:<\/strong> Optical reflectance (dry chemistry colorimetric method, azidomethemoglobin method).<\/p>\n<p><strong>Measured Parameters:<\/strong> Hemoglobin and hematocrit (HCT).<\/p>\n<p><strong>Measurement Speed:<\/strong> Results obtained in 10 seconds or less.<\/p>\n<p><strong>Measurement Range:<\/strong> 4.0 g\/dL to 24.0 g\/dL (results outside this range are indicated by &#8220;Lo&#8221; or &#8220;Hi&#8221;).<\/p>\n<p><strong>Accuracy:<\/strong> \u2265 95%.<\/p>\n<p><strong>Calibration:<\/strong> Factory calibrated according to the ICSH (International Council for Standardization in Haematology) standard.<\/p>\n<p><strong>Memory:<\/strong> Can store up to 250 test results.<\/p>\n<p><strong>Automation:<\/strong> Self-checking, automatic judgment, and malfunction display.<\/p>\n<p><strong>Strip Storage Conditions:<\/strong> Store in a dry, dark place between 0\u00b0C and 30\u00b0C, away from direct sunlight and heat, and not frozen.<\/p>\n<p><strong>Use:<\/strong> Strips should be used immediately after removal from the container; used strips should be disposed of as normal medical waste.<\/p>\n<p><strong>Restrictions on Use:<\/strong> Not for serum, plasma, arterial blood, or patient self-testing; intended for use by healthcare professionals.<\/p>\n","protected":false},"featured_media":18720,"comment_status":"open","ping_status":"closed","template":"","meta":[],"product_brand":[202],"product_cat":[167],"product_tag":[],"class_list":{"0":"post-18719","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_brand-urit","7":"product_cat-consumables","9":"first","10":"instock","11":"taxable","12":"shipping-taxable","13":"product-type-simple"},"_links":{"self":[{"href":"https:\/\/orickmedicosarl.com\/index.php\/wp-json\/wp\/v2\/product\/18719","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/orickmedicosarl.com\/index.php\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/orickmedicosarl.com\/index.php\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/orickmedicosarl.com\/index.php\/wp-json\/wp\/v2\/comments?post=18719"}],"version-history":[{"count":1,"href":"https:\/\/orickmedicosarl.com\/index.php\/wp-json\/wp\/v2\/product\/18719\/revisions"}],"predecessor-version":[{"id":18721,"href":"https:\/\/orickmedicosarl.com\/index.php\/wp-json\/wp\/v2\/product\/18719\/revisions\/18721"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/orickmedicosarl.com\/index.php\/wp-json\/wp\/v2\/media\/18720"}],"wp:attachment":[{"href":"https:\/\/orickmedicosarl.com\/index.php\/wp-json\/wp\/v2\/media?parent=18719"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/orickmedicosarl.com\/index.php\/wp-json\/wp\/v2\/product_brand?post=18719"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/orickmedicosarl.com\/index.php\/wp-json\/wp\/v2\/product_cat?post=18719"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/orickmedicosarl.com\/index.php\/wp-json\/wp\/v2\/product_tag?post=18719"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}