{"id":18921,"date":"2025-09-23T11:01:56","date_gmt":"2025-09-23T11:01:56","guid":{"rendered":"https:\/\/orickmedicosarl.com\/?post_type=product&#038;p=18921"},"modified":"2025-09-23T11:01:56","modified_gmt":"2025-09-23T11:01:56","slug":"complete-knee-solution","status":"publish","type":"product","link":"https:\/\/orickmedicosarl.com\/index.php\/product\/complete-knee-solution\/","title":{"rendered":"Complete Knee Solution"},"content":{"rendered":"<p><strong>Zimmer Biomet&#8217;s NexGen Complete Knee Solution offers several notable features:<\/strong><\/p>\n<p><strong>Implant Interchangeability:<\/strong> Femoral implants are interchangeable with pre-coated stemmed tibial components, A\/P wedges, and trabecular metal tibial components.<\/p>\n<p><strong>Fixation Options:<\/strong> Cemented and cementless options are available for femoral, tibial, and patellar components.<\/p>\n<p><strong>High Range of Motion:<\/strong> CR Flex and LPS Flex components allow for a wide range of motion, with femoral flexion up to 125\u00b0-155\u00b0.<\/p>\n<p><strong>Materials:<\/strong> The implants are composed of non-ferromagnetic materials such as Zimaloy cobalt-chromium-molybdenum alloy, ultra-high molecular weight polyethylene, and titanium-aluminum-vanadium alloy (Ti-6Al-4V).<\/p>\n<p><strong>Kinematic Alignment:<\/strong> This system pioneered the concept of &#8220;kinematic alignment,&#8221; a surgical approach that aims to preserve the natural biomechanics of the joint by recreating the patient&#8217;s pre-arthritis knee motion patterns.<\/p>\n<p><strong>Modularity:<\/strong> The modular design of the NexGen Rotating Hinge (RH) allows for bone preservation and seamless intraoperative conversions from the NexGen Legacy Condylar Constrained Knee (LCCK).<\/p>\n<p><strong>Condylar Loading:<\/strong> The NexGen RH Knee&#8217;s femoral component and articulating surfaces are designed to maintain centralized contact throughout the entire range of motion, ensuring 95% condylar loading through the tibial condyles.<\/p>\n","protected":false},"excerpt":{"rendered":"<p><strong>Zimmer Biomet&#8217;s NexGen Complete Knee Solution offers several notable features:<\/strong><\/p>\n<p><strong>Implant Interchangeability:<\/strong> Femoral implants are interchangeable with pre-coated stemmed tibial components, A\/P wedges, and trabecular metal tibial components.<\/p>\n<p><strong>Fixation Options:<\/strong> Cemented and cementless options are available for femoral, tibial, and patellar components.<\/p>\n<p><strong>High Range of Motion:<\/strong> CR Flex and LPS Flex components allow for a wide range of motion, with femoral flexion up to 125\u00b0-155\u00b0.<\/p>\n<p><strong>Materials:<\/strong> The implants are composed of non-ferromagnetic materials such as Zimaloy cobalt-chromium-molybdenum alloy, ultra-high molecular weight polyethylene, and titanium-aluminum-vanadium alloy (Ti-6Al-4V).<\/p>\n<p><strong>Kinematic Alignment:<\/strong> This system pioneered the concept of &#8220;kinematic alignment,&#8221; a surgical approach that aims to preserve the natural biomechanics of the joint by recreating the patient&#8217;s pre-arthritis knee motion patterns.<\/p>\n<p><strong>Modularity:<\/strong> The modular design of the NexGen Rotating Hinge (RH) allows for bone preservation and seamless intraoperative conversions from the NexGen Legacy Condylar Constrained Knee (LCCK).<\/p>\n<p><strong>Condylar Loading:<\/strong> The NexGen RH Knee&#8217;s femoral component and articulating surfaces are designed to maintain centralized contact throughout the entire range of motion, ensuring 95% condylar loading through the tibial condyles.<\/p>\n","protected":false},"featured_media":18922,"comment_status":"open","ping_status":"closed","template":"","meta":[],"product_brand":[],"product_cat":[214],"product_tag":[],"class_list":{"0":"post-18921","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-mannequins","8":"first","9":"instock","10":"taxable","11":"shipping-taxable","12":"product-type-simple"},"_links":{"self":[{"href":"https:\/\/orickmedicosarl.com\/index.php\/wp-json\/wp\/v2\/product\/18921","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/orickmedicosarl.com\/index.php\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/orickmedicosarl.com\/index.php\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/orickmedicosarl.com\/index.php\/wp-json\/wp\/v2\/comments?post=18921"}],"version-history":[{"count":1,"href":"https:\/\/orickmedicosarl.com\/index.php\/wp-json\/wp\/v2\/product\/18921\/revisions"}],"predecessor-version":[{"id":18923,"href":"https:\/\/orickmedicosarl.com\/index.php\/wp-json\/wp\/v2\/product\/18921\/revisions\/18923"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/orickmedicosarl.com\/index.php\/wp-json\/wp\/v2\/media\/18922"}],"wp:attachment":[{"href":"https:\/\/orickmedicosarl.com\/index.php\/wp-json\/wp\/v2\/media?parent=18921"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/orickmedicosarl.com\/index.php\/wp-json\/wp\/v2\/product_brand?post=18921"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/orickmedicosarl.com\/index.php\/wp-json\/wp\/v2\/product_cat?post=18921"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/orickmedicosarl.com\/index.php\/wp-json\/wp\/v2\/product_tag?post=18921"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}