{"id":19522,"date":"2025-10-07T12:51:21","date_gmt":"2025-10-07T12:51:21","guid":{"rendered":"https:\/\/orickmedicosarl.com\/?post_type=product&#038;p=19522"},"modified":"2025-10-07T12:51:21","modified_gmt":"2025-10-07T12:51:21","slug":"ultrasound-biomicroscopy-system","status":"publish","type":"product","link":"https:\/\/orickmedicosarl.com\/index.php\/product\/ultrasound-biomicroscopy-system\/","title":{"rendered":"Ultrasound Biomicroscopy System"},"content":{"rendered":"<p>The characteristics of an ultrasound biomicroscopy (UBM) system like the one shown include several key aspects, including technology, applications, and benefits.<\/p>\n<p><strong>Technology and Specifications:<\/strong><br \/>\n<strong>High Frequency:<\/strong> Uses very high-frequency ultrasound (e.g., 50 MHz) for high-resolution imaging of the anterior segment of the eye.<br \/>\n<strong>Resolution and Penetration:<\/strong> Provides very high-resolution cross-sectional images with good tissue penetration, allowing visualization of fine structures such as the cornea, iris, ciliary body, and iridocorneal angle.<br \/>\n<strong>Portability:<\/strong> Often designed to be portable, connecting to laptops or desktops via USB, facilitating its use in various clinical environments.<br \/>\n<strong>Integrated Software:<\/strong> Works with dedicated software for image acquisition, analysis, and management, often with measurement and reporting features.<br \/>\n<strong>Specialty Probes:<\/strong> Uses sheathless oscillating probes designed for ocular examination, sometimes with guards and alarms for patient safety.<\/p>\n<p><strong>Clinical Applications:<\/strong><br \/>\n<strong>Anterior Segment Analysis:<\/strong> Allows for detailed examination of the cornea, lens, ciliary body, iris, and iridocorneal angle.<br \/>\n<strong>Glaucoma Diagnosis:<\/strong> Essential for analyzing iridocorneal angle opening and detecting angles at risk of closure.<br \/>\n<strong>Evaluation of Ocular Pathologies:<\/strong> Used in the diagnosis and follow-up of various conditions, including ocular trauma, ciliary body disease, and other anterior segment pathologies.<br \/>\n<strong>Postoperative Follow-up:<\/strong> Allows for screening for complications after filtration surgery and assessment of reasons for surgical failure.<br \/>\nBenefits:<br \/>\n<strong>Detailed Imaging:<\/strong> Provides clear visualization of ocular structures difficult to observe with other methods. Non-invasive: UBM is a non-invasive procedure for analyzing the anterior segment of the eye.<br \/>\n<strong>Versatility:<\/strong> Applicable in a wide range of clinical situations for diagnosis, monitoring, and research in ophthalmology.<\/p>\n","protected":false},"excerpt":{"rendered":"<p>The characteristics of an ultrasound biomicroscopy (UBM) system like the one shown include several key aspects, including technology, applications, and benefits.<\/p>\n<p><strong>Technology and Specifications:<\/strong><br \/>\n<strong>High Frequency:<\/strong> Uses very high-frequency ultrasound (e.g., 50 MHz) for high-resolution imaging of the anterior segment of the eye.<br \/>\n<strong>Resolution and Penetration:<\/strong> Provides very high-resolution cross-sectional images with good tissue penetration, allowing visualization of fine structures such as the cornea, iris, ciliary body, and iridocorneal angle.<br \/>\n<strong>Portability:<\/strong> Often designed to be portable, connecting to laptops or desktops via USB, facilitating its use in various clinical environments.<br \/>\n<strong>Integrated Software:<\/strong> Works with dedicated software for image acquisition, analysis, and management, often with measurement and reporting features.<br \/>\n<strong>Specialty Probes:<\/strong> Uses sheathless oscillating probes designed for ocular examination, sometimes with guards and alarms for patient safety.<\/p>\n<p><strong>Clinical Applications:<\/strong><br \/>\n<strong>Anterior Segment Analysis:<\/strong> Allows for detailed examination of the cornea, lens, ciliary body, iris, and iridocorneal angle.<br \/>\n<strong>Glaucoma Diagnosis:<\/strong> Essential for analyzing iridocorneal angle opening and detecting angles at risk of closure.<br \/>\n<strong>Evaluation of Ocular Pathologies:<\/strong> Used in the diagnosis and follow-up of various conditions, including ocular trauma, ciliary body disease, and other anterior segment pathologies.<br \/>\n<strong>Postoperative Follow-up:<\/strong> Allows for screening for complications after filtration surgery and assessment of reasons for surgical failure.<br \/>\nBenefits:<br \/>\n<strong>Detailed Imaging:<\/strong> Provides clear visualization of ocular structures difficult to observe with other methods. Non-invasive: UBM is a non-invasive procedure for analyzing the anterior segment of the eye.<br \/>\n<strong>Versatility:<\/strong> Applicable in a wide range of clinical situations for diagnosis, monitoring, and research in ophthalmology.<\/p>\n","protected":false},"featured_media":19495,"comment_status":"open","ping_status":"closed","template":"","meta":[],"product_brand":[],"product_cat":[225],"product_tag":[],"class_list":{"0":"post-19522","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-ophtalmology","8":"first","9":"instock","10":"taxable","11":"shipping-taxable","12":"product-type-simple"},"_links":{"self":[{"href":"https:\/\/orickmedicosarl.com\/index.php\/wp-json\/wp\/v2\/product\/19522","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/orickmedicosarl.com\/index.php\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/orickmedicosarl.com\/index.php\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/orickmedicosarl.com\/index.php\/wp-json\/wp\/v2\/comments?post=19522"}],"version-history":[{"count":1,"href":"https:\/\/orickmedicosarl.com\/index.php\/wp-json\/wp\/v2\/product\/19522\/revisions"}],"predecessor-version":[{"id":19523,"href":"https:\/\/orickmedicosarl.com\/index.php\/wp-json\/wp\/v2\/product\/19522\/revisions\/19523"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/orickmedicosarl.com\/index.php\/wp-json\/wp\/v2\/media\/19495"}],"wp:attachment":[{"href":"https:\/\/orickmedicosarl.com\/index.php\/wp-json\/wp\/v2\/media?parent=19522"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/orickmedicosarl.com\/index.php\/wp-json\/wp\/v2\/product_brand?post=19522"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/orickmedicosarl.com\/index.php\/wp-json\/wp\/v2\/product_cat?post=19522"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/orickmedicosarl.com\/index.php\/wp-json\/wp\/v2\/product_tag?post=19522"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}